Peng Wang

Prof. Dr. Peng Wang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
TLTao Lin
Tao Lin
ZWZhan Wang
Zhan Wang
Fangxin HuFangxin Hu
Fangxin Hu
PWPeng Wang
Peng Wang
In order to examine the seismic behavior of high-strength steel extended end-plate connections, a three-dimensional efficient finite-element model in Abaqus was established subjected to cyclic loading at the beam end. Geometrical dimensions, boundary conditions, element types, contact properties between the bolts, end-plate and column flange, and material cyclic constitutive models were described in detail. Geometry and material nonlinearity were adequately considered. In particular, a cyclic plasticity model for high-strength steels was employed that was easily calibrated based on the tension coupon test, so as to describe the complicated cyclic hardening and softening response. The simulated results of the finite-element model were compared to the test ones in terms of both deformation modes and hysteresis loops. The results showed that the bending deformation of the end-plate and column flange was accurately captured, and the gap phenomena among the bolt nuts, the end-plate, and column flange was described in a satisfactory manner as well. The hysteresis loops from the simulation agreed well with the test results, reproducing the pinched shape due to the end-plate gap evolution under cyclic loading as well as the quite plump shape with stable energy dissipation when the panel zone dominated the cyclic response. Therefore, the accuracy of the finite-element model was verified and it provided a strong benchmark tool for investigating the cyclic or seismic performance of this kind of connection. The connection failure including the bolt fracture and cracking in the end-plate needs further numerical study by calibrating accurate material failure models for high-strength steels and bolts.

1 December 2021 in Structures
Verified
Journal Article
Closed access
JPJianrong Pan
Jianrong Pan
RHRuike Huang
Ruike Huang
JXJing Xu
Jing Xu
PWPeng Wang
Peng Wang
ZWZhan Wang
Zhan Wang
JCJin Chen
Jin Chen

6 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYihuan Wang
Yihuan Wang
ZWZhan Wang
Zhan Wang
JPJianrong Pan
Jianrong Pan
PWPeng Wang
Peng Wang
Modified blind bolts (Hollo-Bolt) and a locally strengthened steel tube column in the panel zone were created to overcome the moment-resisting problem for the bolted connections between concrete-filled hollow section columns and open section beams and to enhance the performance of connections. The cyclic loading was conducted on a total of six modified anchored blind bolted flush end-plate connections to concrete-filled steel tube (CFST) columns. The key parameters investigated were the tube wall thickness, end-plate thickness, blind bolt anchorage method, and beam section. The failure mode, hysteretic behavior, strength, stiffness, ductility, and energy dissipation capacity of the connections were analyzed and evaluated with all details. The results indicated that connections with modified anchored blind bolts and locally strengthened steel tubes could avoid the premature failure of CFST column and exhibit an improved behavior with a favorable strength, stiffness, and stiffness degradation. The test observations reveal two representative failure modes, and the tube wall thickness and blind bolt anchorage method have a significant effect on the resultant failure mode. Moreover, the use of thin endplate and weak beam can effectively enhance the hysteretic behavior of joints, ductility, and energy dissipation capacity; and the change in anchoring method has little effect on the stiffness. Finite element (FE) analysis models were established for the aforementioned connections. The numerical models were validated against the experimental results and exhibited good agreement. Finally, based on the component method, an initial stiffness calculation method was established for the connections.

30 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYihuan Wang
Yihuan Wang
ZWZhan Wang
Zhan Wang
JPJianrong Pan
Jianrong Pan
PWPeng Wang
Peng Wang
JQJianGui Qin
JianGui Qin
SCShizhe Chen
Shizhe Chen
As the square steel tube in the tension zone is always the weakest part of moment-resisting joints, modified blind bolts (Hollo-Bolts) and a locally strengthened steel tube in the panel zone were adopted to enhance the joint performance. Cyclic loading tests were carried out on eight anchored blind-bolted extended end-plate joints between square concrete-filled steel tube (CFST) columns and steel beams. The test parameters included the end-plate thickness, steel tube wall thickness, beam section size, local strengthening connection method, blind bolt anchorage method, and stiffeners. The failure mode, hysteretic behavior, stiffness, strength, ductility, strength degradation, stiffness degradation, and energy dissipation capacity of the joints were studied and analyzed. The test results showed that the application of anchored blind bolts and a locally strengthened steel tube can fully utilize the bolt strength and significantly improve the joint performance, especially in terms of strength and strength degradation. The test observations revealed three typical failure modes for the joints, and the failure mode depended on the weakest component. In addition, the local reinforcement of C-channel and change in the anchorage method had a limited effect on the initial stiffness. Greater end-plate thickness and the use of stiffeners significantly increased the joint stiffness and decreased the rate of stiffness degradation. The use of stiffeners also significantly enhanced the ductility and energy dissipation by moving plastic hinge outward from the joints. Finally, finite element analysis (FEA) models were developed and validated against the experimental results, and the stress distribution and force transfer pattern were investigated.

1 October 2020 in Science Progress
Verified
Journal Article
Open access
PDF file
PWPeng Wang
Peng Wang
JPJianrong Pan
Jianrong Pan
ZWZhan Wang
Zhan Wang
BLBin Li
Bin Li
JQJiangui Qin
Jiangui Qin
The bolted angle connections which are simple, fast, cost-effective, high quality, and no site welding have been recognized as their excellent performance. The moment-rotation behavior of both major and minor axis should be both taken into considering, however, the lack of research on minor axis limits the more comprehensive application. Five monotonic tests were carried out to investigate the influence under different parameters, and a new type connection were considered and detailed. Refined finite element models were built to validate the experimental results and to do several parametric analyses on initial rotational stiffness and plastic moment resistance, including of a presence of stiffened seat angle, angle thickness, and prying force. Furthermore, a new simplified plate method was proposed for calculating stiffness of stiffened angle and web in bending. The stiffened angle gives a significant increase at the moment-resisting capacity and the initial stiffness, the ultimate rotation of all tested specimens was beyond 0.067rad. The initial stiffness and plastic moment resistance of the joints were also controlled by the column web. The presence of the stiffener in the compression zone has the none effect on initial stiffness. The numerical analysis has captured the failure reason for weld and more attention should be paid to welding of stiffener in engineering design and practice. Adding stiffener at the top-and-seat angle joint can reduce the prying force of bolt, but it still cannot be ignored. The theoretical results were in good agreement with the experimental data and finite element results; therefore, it can be used to guide the design and selection of joints.

13 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DZDongzhuo ZHAO
Dongzhuo ZHAO
ZWZhan Wang
Zhan Wang
JPJianrong Pan
Jianrong Pan
PWPeng Wang
Peng Wang
Due to the limitations of processing errors, test conditions and other factors, geometric similarity errors in scale tests of steel structure joints are difficult to avoid, but the research on this error is little known. Based on the similarity theory and the basic idea of the component method, this paper deduces the similar macro conditions of beam–column end-plate connections and derives the main influencing factors of geometric similarity of these types of structures. Aiming at the factor of the thickness of the end-plate, the formation mechanism of the geometrically incomplete similarity error of this type of node was studied. Through the establishment of accurate finite element models for parameterized analysis, the influence of end plate thickness on incomplete similarity error is analyzed. Based on this model and linear regression analysis methods, the prediction formulas of geometric incomplete similarity errors of beam–column end-plate connections have been established, which can significantly reduce similar errors due to end plate thickness. This article aims to propose a method for simulating the distribution of incompletely similar errors and provide a reference for the research of similar problems.