Pedro Nuno Santos

Mr. Pedro Nuno Santos

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2008 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
PBP. D. Batista
P. D. Batista
BDB. Drescher
B. Drescher
WSW. Seidel
W. Seidel
JRJ. Rudolph
J. Rudolph
SJShasha Jiao
Shasha Jiao
PSPedro Nuno Santos
Pedro Nuno Santos
We demonstrate a monolithic acousto-optic light modulator on silicon consisting of a piezoelectric ZnO∕SiO2 microcavity (MC) excited by a surface acoustic wave (SAW). The modulation of the MC optical resonance by the SAW creates an optical grating on the MC, which efficiently diffracts light beams impinging at the Bragg angle.

6 November 2023 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
MJMinhyun Jin
Minhyun Jin
SLSangyeon Lee
Sangyeon Lee
PSPedro Nuno Santos
Pedro Nuno Santos
JKJubin Kang
Jubin Kang
EGEpimitheas Georgitzikis
Epimitheas Georgitzikis
JLJiwon Lee
Jiwon Lee
In this article, the X-ray radiation effects on colloidal quantum dot photodiode (QDPD)-based short-wave infrared (SWIR) complementary metal-oxide semiconductor image sensors (QD-CISs) are studied. Individual QDPD, silicon readout IC (Si-ROIC), and QD-CIS are evaluated together for a comprehensive analysis. The dark current, activation energy, and external quantum efficiency (EQE) of samples are investigated before and after irradiating with 58.2 keV of X-ray radiation, which has a different total ionizing dose (TID) range from 22 to 220 krad. X-ray irradiation on Si-ROIC induces mid-band gap trap states and increases the dark current according to the increasing TID. However, for the QDPD, despite an increase in the TID, the dark current reduces and the EQE slightly enhances at the SWIR wavelength. The QD-CIS shows a decrease in the dark current like the QDPD results, as the TID increases. The activation energy of QD-CIS rarely changes regardless of TID amounts. The X-ray radiation effect on QDPD results in enhanced performance, and this effect continues in the integrated QD-CIS, whereas the effect of Si-ROIC degradation is minor in the current experimental range. Thus, these findings provide significant insights into the utilization of QD-CIS in various X-ray applications.

1 July 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
PSPedro Nuno Santos
Pedro Nuno Santos
IHIdham Hafizh
Idham Hafizh
Paul LerouxPaul Leroux
Paul Leroux
GMG. Meynants
G. Meynants
This article presents a new global shutter (GS) pixel design with radiation-hardened-by-design (RHBD) device modifications and correlated double sampling (CDS). Global shutter imagers present undeniable advantages by exposing all pixels simultaneously. Once in-pixel storage is included, the pixel readout can be operated simultaneously with exposure, enabling faster operation and flashed light. Additionally, this architecture is robust against motion defects and easy to operate in synchronous mode. The radiation tolerance of the outlined pixel is targeted up to 1 MGy SiO2 total ionizing dose (TID). A partially pinned photodiode (pPPD) structure, combined with an enclosed transistor layout known as a “butterfly” [1,2] is used to withstand such a high TID value. The use of the p+ implant on top of the photodiode and recessed shallow trench isolation (STI) reduce the dark current from the TID-induced interface traps and SiO2 interface while also shielding the photodiode (PD) region from TID-induced positive charges in the SiO2. CDS [3] is required to reduce the read noise by suppressing important noise sources such as photon shot noise, thermal noise (kTC) and flicker noise contributions. Two in-pixel storage capacitors and two readout paths are implemented to allow CDS. The pixel operation includes a sample phase where the pixel signal is locally stored followed by a reset phase and the pixel reset is stored. The in-pixel storage is designed with enclosed butterfly MOS devices that allow great charge density for low area and with limited leakage due to the RHBD design. The readout is performed by operating two output source followers (SF) and two output buses. The pixel is designed using 180 nm CMOS Image Sensor (CIS) technology. It achieves a pre-rad dynamic range of 60.9 dB and a shutter efficiency of 99,6%.

14 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PSPedro Nuno Santos
Pedro Nuno Santos
IHIdham Hafizh
Idham Hafizh
Paul LerouxPaul Leroux
Paul Leroux
GMGuy Meynants
Guy Meynants
A 10 × 10 µm2 radiation-tolerant voltage-domain global shutter pixel with radiation-hardened by design (RHBD) device modification is developed to operate under high ionizing-dose rates and high total ionizing-dose (TID) levels. Therefore, a modified NMOS transistor layout is used in the pixel to achieve radiation hardness. The pixel design is demonstrated to operate up to 1 MGy or 100 Mrad (SiO2) TID with minimal degradation. The global shutter pixel also includes correlated double sampling (CDS) to reduce noise and the impact of the collected carriers generated by the flux of gamma or X-ray radiation. Combined with an external flash, global shutter operation allows short exposures, which limits the impact of radiation on dark current and dynamic range. The pixel is designed using 180 nm CMOS Image Sensor (CIS) technology.

11 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MJMinhyun Jin
Minhyun Jin
SPSeungah Park
Seungah Park
PSPedro Nuno Santos
Pedro Nuno Santos
JCJung-Hoon Chun
Jung-Hoon Chun
GMGuy Meynants
Guy Meynants
SLSangyeon Lee
Sangyeon Lee
Short-wavelength infrared (SWIR) image sensors are of increasing interest for space applications, where ionizing radiation can significantly impact device performance. PbS colloidal quantum dot (CQD)-based thin-film photodiodes (TFPDs) are promising candidates due to their spectral tunability and compatibility with CMOS integration. However, their radiation response remains insufficiently understood. We investigated the effects of X-ray irradiation on PbS CQD-based SWIR TFPDs and image sensors up to a total ionizing dose of 220 krad. The results suggest that X-ray irradiation induces ligand-dependent modulation of the trap-state in PbS CQD films, leading to reduced recombination and enhanced carrier lifetime. Consequently, the TFPDs exhibit decreased dark current and improved external quantum efficiency (EQE), reaching 44.2% at 1420 nm. PbS CQD-based SWIR image sensors maintain stable operation after irradiation until 220 krad, achieving an EQE of 33.1%. These results provide an initial assessment of PbS CQD-based SWIR image sensors under X-ray total ionizing dose (TID) exposure, highlighting the importance of ligand-dependent CQD surface chemistry towards SWIR photodetectors in space applications.