Luminita Daguci

Dr. Luminita Daguci


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
MIMihaela Ionescu
Mihaela Ionescu
Horia Octavian ManoleaHoria Octavian Manolea
Horia Octavian Manolea
VMVeronica Mercuț
Veronica Mercuț
EOEugenia Obădan
Eugenia Obădan
Mihaela PopescuMihaela Popescu
Mihaela Popescu
The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann–Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = −2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.

Ruxandra Sava-RosianuRuxandra Sava-Rosianu
Ruxandra Sava-Rosianu
Guglielmo CampusGuglielmo Campus
Guglielmo Campus
AMAnamaria Matichescu
Anamaria Matichescu
OBOctavia-Iulia Bălean
Octavia-Iulia Bălean
MDMihaela Adina Dumitrache
Mihaela Adina Dumitrache
Atena GaluscanAtena Galuscan
Atena Galuscan
Oral health-related behaviors and living conditions play an important role in general and oral health. This study aimed to evaluate caries prevalence and severity in schoolchildren residing in rural and urban areas of Romania, and to correlate these with oral health-related behaviors. An estimation of the required sample size was conducted (sampling error of ±3% at a 95% confidence level), followed by the stratification of administrative units and then the selection of 49 schools. The Hurdle approach was used to analyze the dataset, requiring two sets of analyses for each outcome variable: a multilevel binary model to predict prevalence, and a multilevel Poisson analysis using only non-zero values. The mean and standard deviation (SD) for the dentinal caries index was 4.96 (5.33). Girls were more likely to have non-zero restoration codes (β = 0.14, SE = 0.08, p < 0.05). Low education levels of each parent were associated with an increased likelihood of having non-zero carious tooth surfaces (β = 0.23, SE = 0.06, p = 0.01; β = 0.22, SE = 0.06, p < 0.01). The presence of cavities was predicted by the consumption of carbonated soft drinks (β = 0.19, SE = 0.07, p < 0.01), candies (β = 0.13, SE = 0.06, p < 0.01), sweetened milk (β = 0.12, SE = 0.06, p < 0.05), tea (β = 0.16, SE = 0.08, p < 0.05), or cocoa (β = 0.13, SE = 0.06, p < 0.05). Furthermore, the non-zero values of the dentinal caries index were more likely in rural schools (β = −0.37, SE = 0.11, p < 0.01), and a negative association between the county development index and the fillings/restorations index (β = −0.01, SE = 0.01, p < 0.05) was also established. The outcome of this research highlights that the presence of caries (dentinal caries index) in Romanian schoolchildren is influenced by their socioeconomic background, as well as their specific consumption behaviors.

Verified
Journal Article
Open access
PDF file
MNManuela Maria Nardin
Manuela Maria Nardin
AIAlin Gabriel Ionescu
Alin Gabriel Ionescu
ADAlexandra Elena Done
Alexandra Elena Done
CMCosmin Mihai Miritoiu
Cosmin Mihai Miritoiu
PPPaula Adriana Padeanu
Paula Adriana Padeanu
VMVeronica Mercuț
Veronica Mercuț
The success of orthodontic therapy depends on the effective, continuous application of forces to teeth. Therefore, an essential element of the treatment is the adhesion between the bracket and enamel. The purpose of this study was to evaluate the influence of bracket base design and bonding system on shear bond strength. The study was conducted on eighty extracted premolars which were randomly divided into four groups of twenty teeth each, using two types of metal brackets (80-gauge mesh and anchor pylons base design) and two types of bonding systems (conventional and self-etching). The combination of bracket and bonding system resulted in four distinct configurations of bracket bonding, with each configuration tested on twenty teeth. Shear bond strength testing was performed using a Laryee Universal Testing Machine. The obtained values were statistically analyzed. Slightly higher shear bond strength values were recorded for brackets with anchor pylons bonded using the conventional bonding system (13.32 ± 4.20 N/mm2), whereas the lowest values were recorded for the same bracket base design bonded with the self-etching system (11.10 ± 4.50 N/mm2). Nevertheless, ANOVA test did not reveal statistically significant differences between the two bracket types or between the two bonding techniques in terms of shear bond strength and force values and no significant interaction effects were observed. Considering the obtained results, several additional factors must be taken into account when evaluating the shear bond strength of orthodontic brackets.

4 July 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MNManuela Maria Nardin
Manuela Maria Nardin
MBMihaela Roxana Botila
Mihaela Roxana Botila
CPCristina Teodora Preoteasa
Cristina Teodora Preoteasa
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
VMVeronica Mercuț
Veronica Mercuț
Background/Objectives: This “in silico” study investigated the biomechanical behavior of fixed orthodontic systems by analyzing the forces generated by Ni–Ti archwires and their effects on the dento-maxillary system (DMS). The objectives were to estimate force levels for 0.012″, 0.014″, and 0.016″ archwires and to evaluate the resulting stress distribution, displacement and deformation, including the influence of dental malpositions such as infraposition and linguoposition on force transmission. Methods: A three-dimensional (3D) patient-specific model of the DMS was developed and finite element analysis (FEM) was performed. Orthodontic forces were determined analytically based on archwire deformation and applied as equivalent force systems at the bracket level. The analysis was performed under simplified assumptions, including linear elastic material behavior and the absence of bracket–archwire friction. Results: The results indicated a direct relationship between archwire diameter and force magnitude. Increased diameter was associated with higher stress, displacement and deformation values. Simulated infraposition and linguoposition produced localized variations in stress distribution, highlighting the influence of tooth position on biomechanical response. Conclusions: Within the limitations of the simplified analytical and numerical model, archwire diameter plays a significant role in determining force magnitude and stress distribution in orthodontic systems. The findings provide a comparative framework for understanding force transmission, although the results should be interpreted as theoretical estimates under idealized conditions rather than direct predictors of clinical behavior.

29 June 2026 in Romanian Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
ABAdina Magdalena Bunget
Adina Magdalena Bunget
PMPetre Costin MărășEscu
Petre Costin MărășEscu
IDIonela Teodora Dascălu
Ionela Teodora Dascălu
PPPaula Perlea
Paula Perlea
DBDana Cristina Bodnar
Dana Cristina Bodnar
FMFelicia Ileana Mărășescu
Felicia Ileana Mărășescu

26 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MAMarina Amărăscu
Marina Amărăscu
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
AIAlin Gabriel Ionescu
Alin Gabriel Ionescu
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
RRRadu Gabriel Rîcă
Radu Gabriel Rîcă
AKAntonia Samia Khaddour
Antonia Samia Khaddour
The selection of the impression technique is an essential process that must be carried out according to the needs of each patient and the complexity of each clinical case. Impression methods have specific advantages, and their selection can directly influence the quality of the final result, the stability and long-term success of the prosthetic restoration, but also the patient's comfort. Objectives: The purpose of this study was to compare conventional and digital impression techniques, highlighting the advantages and limitations of each and their clinical implications. Materials and Methods: The study was conducted based on the results of an online questionnaire comprising 16 items, distributed to dentists in the Oltenia region of Romania. The collected data were statistically analyzed, and correlations among variables were established. Results: The study highlights a high acceptance rate of digital impression techniques among dentists in Oltenia, with preference among doctors from urban areas and the 36-45-year age group. Digital impression techniques are associated with superior clinical accuracy, increased patient comfort, and high levels of professional satisfaction despite their high initial costs. The results confirm that direct experience with digital technologies significantly influences doctors' willingness to adopt and recommend this method. Conclusions: Although digital impression techniques are increasingly adopted, conventional techniques remain indispensable in numerous clinical scenarios owing to their proven reliability and adaptability.