Traditional approach of spectroscopy signals acquisition and analysis comprises digitization performed ideally by a high bit resolution and short sampling period flash ADC, followed by a subsequent digital processing requiring a high computational performance. However, some particular applications cannot implement that traditional approach while demanding comparable high spectroscopic performance due to hardware limitations mainly given by operational conditions, availability of qualified electronic components, power consumption limit, etc. The Dynamic Time Over Threshold (DTOT) conversion method-based processing of spectroscopy signals represents an undemanding alternative in contrary to that traditional approach. The detailed study of DTOT method-based processing was performed with the aim to maximize achievable performance via extension of the dynamic range allowing to process a wide span of input spectroscopy signals. The contribution also presents practical implementation of front-end electronics integrating an enhanced DTOT converter structure dedicated to a gamma detector (based on sensors of SiPM type) while test measurements with common reference radiation sources were performed to provide comparative results.
16 February 2026 in IEEE Transactions on Nuclear Science
Silicon Photomultipliers (SiPMs) have become an integral part of time-of-flight positron emission tomography (TOF-PET) scanners in recent years. Their excellent photodetection efficiency and fast decay time are essential in state-of-the-art timing resolutions, which have enabled improvements in image quality for TOF-PET. However, most SiPMs share a common architecture: an array of single avalanche photodiodes. This design has a limitation: each pixel requires its own quenching resistor and conductive connections, creating inactive regions that reduce the effective detection area. In this paper we explored a new type of SiPMs called the Micropixel Avalanche Photodiodes (MAPD) for the purposes of TOF-PET. These devices utilize buried pixel technology, which minimizes detector dead zones and achieves an almost 100 % fill factor. We evaluated their noise characteristics, energy resolution, and coincidence timing resolution (CTR). Our findings indicate that although the MAPD-3NM-II devices exhibit higher dark count rates, notable optical cross-talk, and a narrower overvoltage range compared to the reference Hamamatsu S14160-3015PS SiPMs, they offer superior energy resolution—improving up to 17 % at 511 keV—while maintaining competitive timing performance at the same overvoltage. In particular, with 3.8×3.8×4 mm3 LYSO crystals, the MAPD-3NM-II achieved a CTR of 336 ± 12 ps, a 5% improvement compared to Hamamatsu at the same overvoltage. Despite operating only up to 4.5 V, the MAPD-3NM-II demonstrates strong potential for TOF-PET applications, especially in scenarios prioritizing energy resolution. Further structural optimizations to reduce cross-talk and expand the operable voltage range could make this technology a competitive alternative to established SiPM architectures.
Multi-channel analysers (MCAs) play a crucial role in spectral measurements, especially in the context of Silicon Photomultipliers (SiPMs) used for gamma spectroscopy. Most commercial MCAs, while highly accurate, remain cost-prohibitive for broader applications. This paper presents the design and implementation of a cost-effective MCA utilizing off-the-shelf components while achieving spectroscopy of gamma particles with reasonable resolution. The MCA board is built around the STM32G4 family microcontroller (MCU), which provides embedded analog components, timers, and high-resolution ADCs. This system is designed to reduce external component requirements, thereby decreasing costs and increasing system reliability. Experimental results demonstrate that the MCA can perform accurate real-time gamma radiation measurements with SiPM detectors. The device offers flexible connectivity options (USB, Ethernet, WiFi). The low-cost, accessible nature of the MCA opens up opportunities for educational and research applications in radiation detection.
This study examines the design, manufacturing, and testing of planar PCB inductors (spiral and toroid), including multilayer PCB toroid configurations. These inductors are intended for environments with strong magnetic fields, such as high-energy physics experiments and medical applications, where traditional inductors with ferromagnetic cores are unsuitable. Twelve inductor samples were manufactured and tested. The focus was on maximizing inductance and evaluating performance in a high-frequency DC-DC step-down converter. Key parameters measured included inductance, resistance, thermal performance, electromagnetic interference (EMI), and frequency-dependent behavior in multilayer PCB implementations. The results showed that planar spiral inductors handled higher currents and achieved better efficiency, reaching up to 74.86%. Planar toroid inductors were more tolerant of added shielding, maintaining their inductance, while multilayer toroid designs exhibited reduced DC resistance but increased frequency dependence and sensitivity to parasitic effects. Overall, planar inductors were found to be viable for applications where ferromagnetic cores are unsuitable. Further optimization of geometry, layer configuration, and manufacturing processes could enhance their performance.
Multi-channel analysers (MCAs) play a crucial role in spectral measurements, especially in the context of Silicon Photomultipliers (SiPMs) used for gamma spectroscopy. Most commercial MCAs, while highly accurate, remain cost-prohibitive for broader applications. This paper presents the design and implementation of a cost-effective MCA utilizing off-the-shelf components while achieving spectroscopy of gamma particles with reasonable resolution. The MCA board is built around the STM32G4 family microcontroller (MCU), which provides embedded analog components, timers, and high-resolution ADCs. This system is designed to reduce external component requirements, thereby decreasing costs and increasing system reliability. Experimental results demonstrate that the MCA can perform accurate real-time gamma radiation measurements with SiPM detectors. The device offers flexible connectivity options (USB, Ethernet, WiFi). The low-cost, accessible nature of the MCA opens up opportunities for educational and research applications in radiation detection.
Background Compact electronic modules are essential for modern detector systems utilizing Silicon Photomultiplier (SiPM) arrays due to their small size, low power consumption, and high precision. To address the growing demand for portable and efficient detection systems, the development of modules tailored for such applications has become a critical focus. This study introduces compact electronic modules designed for detectors based on MAPD (Microcell Avalanche Photodiode) arrays, aiming to improve reliability and versatility for industrial, medical, and scientific applications. Methods The developed modules include two primary components: DC-DC Voltage Converter: Based on the MAX1932ETC chip. Converts a 5 V input to a stable output voltage adjustable between 30 and 90 V. Supports a maximum current of 2.5 mA, ensuring reliable operation for SiPM arrays. Signal Amplification Unit: Utilizes the LTC6268 chip. Processes input signals ranging from 10 to 75 mV. Offers a gain factor of 45, characterized by low noise and high precision. The modules were integrated with a scintillation detector comprising a MAPD-3NM-II photodiode array and an LFs scintillator. Performance testing was conducted using a Cs-137 gamma source. Results The energy resolution of the detector system was evaluated using the 662 keV gamma line from the Cs-137 source. The modules achieved an energy resolution of 10 ± 0.5%, demonstrating high reliability and efficiency. This performance confirms the modules’ capability to maintain stable operation and precise signal processing under real-world conditions. Conclusions The developed compact electronic modules provide a cost-effective and efficient solution for detectors utilizing SiPM arrays. Their stable voltage conversion, low-noise signal amplification, and high energy resolution make them suitable for a wide range of applications in industrial, medical, and scientific fields. Future work may focus on optimizing the modules for broader voltage ranges and compatibility with different scintillator materials to expand their applicability.