Ondrej Ruzicka

Mr. Ondrej Ruzicka

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2025 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
MZMarek Zmeškal
Marek Zmeškal
PBPetr Burian
Petr Burian
MKMichal Košťál
Michal Košťál
TCTomáš Czakoj
Tomáš Czakoj
TPTomáš Peltan
Tomáš Peltan
ŠVŠimon Vadják
Šimon Vadják

17 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PBPetr Burian
Petr Burian
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
PBPavel Broulím
Pavel Broulím
MFMartin Farkaš
Martin Farkaš
TKTomáš Kulhánek
Tomáš Kulhánek
JZJan Zich
Jan Zich
This work presents a novel readout system for the Timepix3-based detector, designed specifically for large-scale facilities, such as particle accelerators. The authors begin by outlining the challenges associated with utilizing the Timepix3 detector over long distances. This paper proposes a solution to these challenges and describes its practical implementation. Beam test results are provided to demonstrate the system’s performance, with a particular focus on time-of-flight measurements. Additionally, the authors address the complexities of operating in challenging environments, particularly those involving radiation and magnetic fields.

1 June 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
OROndrej Ruzicka
Ondrej Ruzicka
PBPetr Burian
Petr Burian
PBPavel Broulím
Pavel Broulím
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
TKT. Kulhánek
T. Kulhánek
PSPetr Smolyanskiy
Petr Smolyanskiy
This paper presents a modular readout and chipboard concept developed for the Timepix4 hybrid pixel detector, a high-performance ASIC featuring 448 × 512 pixels and sub-nanosecond timing resolution. Building on the success of Timepix3, Timepix4 supports both frame-based and data-driven acquisition modes with data rates up to 3.6 MHits/mm2/s and 195 ps time binning. The chip can be integrated via wire-bonding or Through-Silicon-Via (TSV) technology, allowing full four-side tiling for scalable detector arrays. The modular chipboard system, consisting of a detector module and a baseboard, simplifies power delivery and data transmission using a single 12 V supply and Ethernet-style cabling. A commercial FPGA-based readout supports up to four detectors with Gigabit Ethernet and PCIe interfaces. The concept was successfully validated at CERN SPS with heavy-ion beams, demonstrating system stability and high data integrity. Ongoing development focuses on enhanced power and cooling systems, multi-chip integration, and improved software support for advanced experimental setups.

1 June 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
PBPetr Burian
Petr Burian
PBPavel Broulím
Pavel Broulím
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
MFMartin Farkaš
Martin Farkaš
MJM. Jára
M. Jára
Petr MánekPetr Mánek
Petr Mánek
This paper presents Katherine Generation 2 (Gen2), an advanced readout system designed for Timepix3 pixel detector. The new system addresses limitations of the original Katherine (Gen1) design, particularly in terms of data throughput and support for multi-detector configurations. Katherine Gen2 supports two sensor inputs via VHDCI connectors and provides two independent bias voltage sources up to ±1 kV. It includes both Gigabit Ethernet and USB 3.0 interfaces, offering flexibility for remote or local high-throughput applications. Data handling pipeline has been extended to support dynamic detector mapping, hardware decoding of pixel data, and timestamping of external triggers. Compatibility with multiple chipboard types, including single-chip, quad (2× 2), and specialized detector units, is maintained. Benchmark measurements demonstrate that the system achieves the maximum data rate supported by the Timepix3 chip in USB 3.0 mode. The device is supported by established software tools and is intended as a flexible platform for various experimental and detector development applications.

1 February 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
PKPatrik Kučera
Patrik Kučera
OUO. Urban
O. Urban
OROndrej Ruzicka
Ondrej Ruzicka
MVM. Vítek
M. Vítek
PSP.M. Stašek
P.M. Stašek
TSTomáš Slavíček
Tomáš Slavíček
Multi-channel analysers (MCAs) play a crucial role in spectral measurements, especially in the context of Silicon Photomultipliers (SiPMs) used for gamma spectroscopy. Most commercial MCAs, while highly accurate, remain cost-prohibitive for broader applications. This paper presents the design and implementation of a cost-effective MCA utilizing off-the-shelf components while achieving spectroscopy of gamma particles with reasonable resolution. The MCA board is built around the STM32G4 family microcontroller (MCU), which provides embedded analog components, timers, and high-resolution ADCs. This system is designed to reduce external component requirements, thereby decreasing costs and increasing system reliability. Experimental results demonstrate that the MCA can perform accurate real-time gamma radiation measurements with SiPM detectors. The device offers flexible connectivity options (USB, Ethernet, WiFi). The low-cost, accessible nature of the MCA opens up opportunities for educational and research applications in radiation detection.

1 February 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
TKT. Kulhánek
T. Kulhánek
OROndrej Ruzicka
Ondrej Ruzicka
JZJ. Zich
J. Zich
VGV. Georgiev
V. Georgiev
This paper presents the concept and development of a system for digitizing analog signals from particle detectors. The system is designed to achieve very high sampling rates through interleaved analog-to-digital conversion. At the same time, it maintains modularity, enabling flexible channel configurations and system scalability. The prototype employs state-of-the-art analog-to-digital converters (AD9213, 12-bit, up to 10.25 GS/s) and FPGA-based processing with data transfer implemented via the JESD204B interface. The system also employs interleaved sampling to achieve very high effective sampling rates. The functionality of the system was verified on the prototype using both sine-wave test signals and real signals from a fast photomultiplier tube. The results demonstrate reliable digitization of ultra-fast pulses with widths of only a few nanoseconds, including the observation of pile-up effects. Future development will focus on extending the FPGA firmware and data acquisition software capabilities and integrating additional analog front-end circuitry such as amplifiers and signal-conditioning stages. These enhancements are expected to further increase the applicability of the platform in time-of-flight measurements and other high-speed detector readout systems.