Mohammad Hussain

Dr. Mohammad Hussain

King Khalid University, Abah, saudi Arabiah
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OAOmar Azeem
Omar Azeem
MAMujtaba Ali
Mujtaba Ali
Ghulam AbbasGhulam Abbas
Ghulam Abbas
MUMuhammad uzair
Muhammad uzair
Ayman QahmashAyman Qahmash
Ayman Qahmash
Mohammad HussainMohammad Hussain
Mohammad Hussain
The depletion of natural resources and the intermittence of renewable energy resources have pressed the need for a hybrid microgrid, combining the benefits of both AC and DC microgrids, minimizing the overall deficiency shortcomings and increasing the reliability of the system. The hybrid microgrid also supports the decentralized grid control structure, aligning with the current scattered and concentrated load scenarios. Hence, there is an increasing need to explore and reveal the integration, optimization, and control strategies regarding the hybrid microgrid. A comprehensive study of hybrid microgrid’s performance parameters, efficiency, reliability, security, design flexibility, and cost-effectiveness is required. This paper discusses major issues regarding the hybrid microgrids, the integration of AC and DC microgrids, their security and reliability, the optimization of power generation and load management in different scenarios, the efficient management regarding uncertainty for renewable energy resources, the optimal placement of feeders, and the cost-effective control methodologies for the hybrid microgrid. The major research areas are briefly explained, aiming to find the research gap that can further improve the performance of the grid. In light of the recent trends in research, novel strategies are proposed that are found most effective and cost-friendly regarding the hybrid microgrid. This paper will serve as a baseline for future research, comparative analysis, and further development of novel techniques regarding hybrid microgrids.

26 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
FTFaisal Tariq
Faisal Tariq
SAsalelyani Alelyani
salelyani Alelyani
Ghulam AbbasGhulam Abbas
Ghulam Abbas
Ayman QahmashAyman Qahmash
Ayman Qahmash
Mohammad HussainMohammad Hussain
Mohammad Hussain
One of the most important concerns in the planning and operation of an electric power generation system is the effective scheduling of all power generation facilities to meet growing power demand. Economic load dispatch (ELD) is a phenomenon where an optimal combination of power generating units is selected in such a way as to minimize the total fuel cost while satisfying the load demand, subject to operational constraints. Different numerical and metaheuristic optimization techniques have gained prominent importance and are widely used to solve the nonlinear problem. Although metaheuristic techniques have a good convergence rate than numerical techniques, however, their implementation seems difficult in the presence of nonlinear and dynamic parameters. This work is devoted to solving the ELD problem with the integration of variable energy resources using a modified directional bat algorithm (dBA). Then the proposed technique is validated via different realistic test cases consisting of thermal and renewable energy sources (RESs). From simulation results, it is observed that dBA reduces the operational cost with less computational time and has better convergence characteristics than that of standard BA and other popular techniques like particle swarm optimization (PSO) and genetic algorithm (GA).

7 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RMRaheel Muzzammel
Raheel Muzzammel
Ali RazaAli Raza
Ali Raza
Mohammad HussainMohammad Hussain
Mohammad Hussain
Ghulam AbbasGhulam Abbas
Ghulam Abbas
IAIshtiaq Ahmad
Ishtiaq Ahmad
MKMohammed Khaleel
Mohammed Khaleel
Estimation of fault classification and location in a multi-terminal high voltage direct current (MT–HVdc) transmission system is a challenging problem and is considered to be a fundamental maneuver of dc grid protection. This research paper critically reviews traveling and non-travelling wave methods of classification and location of dc faults in multi-terminal HVdc transmission systems. Detailed mathematical analysis of MT–HVdc systems composed of high grounding resistance, cable and overhead line segments, and bipolar coupled transmission network under healthy and faulty conditions, are evaluated. The gravity of this research paper addresses benefits and shortcomings of traveling and non-traveling wave methods and futuristic techniques of fault classification and location.

26 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMuhammad Arslan Shahid
Muhammad Arslan Shahid
Ghulam AbbasGhulam Abbas
Ghulam Abbas
Mohammad HussainMohammad Hussain
Mohammad Hussain
MAMuhammad Usman Asad
Muhammad Usman Asad
UFUmar Farooq
Umar Farooq
TYTanveer Yazdan
Tanveer Yazdan
This paper presents an intelligent voltage controller designed on the basis of an adaptive neuro-fuzzy inference system (ANFIS) for a flyback converter (FC) working in continuous conduction mode (CCM). The union of fuzzy logic (FL) and adaptive neural networks (ANN) makes ANFIS more robust against model parameters’ uncertainties and perturbations in input voltage or load current. ANFIS inherits the advantages of structured knowledge representation from FL and learning capability from NN. Comparative analysis showed that the ANFIS controller offers not only the superior transient response characteristics, but also excellent steady-state characteristics compared to those of the FL controller (FLC) and proportional–integral–derivative (PID) controllers, thus validating its superiority over these traditional controllers. For this purpose, MATLAB/Simulink environment-based simulation results are presented for validation of the proposed converter compensated system under all operating conditions.

21 February 2025 in IEEE Access
Verified
Journal Article
Open access
WKWasim Khan
Wasim Khan
MIMohammad Ishrat
Mohammad Ishrat
MAMohammad Nadeem Ahmed
Mohammad Nadeem Ahmed
SAShafiqul Abidin
Shafiqul Abidin
MHMohammad Husain
Mohammad Husain
Arshad AliArshad Ali
Arshad Ali
The increasing relevance of anomaly detection in attributed networks is gaining traction in fields such as cybersecurity, finance, and healthcare. However, large-scale attributed networks often exhibit noisy and inconsistent node properties, which negatively affect anomaly detection accuracy and disrupt the network’s structure. A key challenge is maintaining the integrity of both network and node feature structures during the embedding process. To address this, we propose a novel approach that combines a Graph Convolution Auto encoder (GCAE) with self-supervised learning, proximity preservation, and adversarial training using Generative Adversarial Networks (GAN). First, Laplacian smoothing is applied to reduce noise in node properties, followed by Laplacian sharpening to highlight important features. These enhanced features are then fed into the GCAE, which encodes node attributes into a latent space using graph convolutional layers. Self-supervised tasks like attribute masking and edge prediction further enhance the GCAE’s ability to capture the graph’s structure. Additionally, proximity preservation ensures that the latent space reflects both first order and high-order proximity. The inclusion of GAN refines the embedding’s, aligning them closer to the true distribution of the graph data. This method effectively preserves both node features and network structure, making the embedding robust and distinguishable. Empirical evaluations on four real-world datasets demonstrate that our approach surpasses state-of-the-art methods, setting a new benchmark for anomaly detection in attributed networks. Our framework has significant potential to advance both research and practical applications in anomaly detection.

25 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Ghulam AbbasGhulam Abbas
Ghulam Abbas
MAMuhammad Usman Asad
Muhammad Usman Asad
JGJason Gu
Jason Gu
SAsalelyani Alelyani
salelyani Alelyani
Valentina Emilia BalasValentina Emilia Balas
Valentina Emilia Balas
CCChunqi Chang
Chunqi Chang
Most of the traditional PID tuning methods are heuristic in nature. The heuristic approach-based tuned PID controllers show only nominal performance. In addition, in the case of a digital redesign approach, mapping of the heuristically-designed continuous-time PID controllers into discrete-time PID controllers and in case of the direct digital design approach, mapping of the continuous-time plant (forward converter) into the discrete-time plant, results in frequency distortion (or warping). Besides this, nonlinear elements such as ADC and DAC, and delay in the digital control loop deteriorate the control performance. There is a need to tune conventionally-designed digital controllers to enhance performance. This paper proposes optimized discrete-time PID controllers for a forward DC–DC converter operating in continuous conduction mode (CCM). The considered conventional digital PID controllers designed on the basis of the digital redesign and direct digital approaches are tuned by one of the multivariable unconstrained pattern search methods named Hooke–Jeeves (H–J) search method to ensure excellent output voltage regulation performance against the changes in input voltage and load current. Numerical results show that the H–J-based optimized PID compensated forward converter system shows tremendous improvement in performance compared to its unoptimized counterpart and simulated annealing (SA)-based compensated system, thus justifying the applicability of the H–J method for enhancing the performance.