Antonín Trefil

Antonín Trefil

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Sadaqat AliSadaqat Ali
Sadaqat Ali
MIMuhammad Irfan
Muhammad Irfan
UKUsama Khan
Usama Khan
ARAhmad Majdi Abdul Rani
Ahmad Majdi Abdul Rani
ARA M Mabrur Ahmad Rashedi
A M Mabrur Ahmad Rashedi
ATAntonín Trefil
Antonín Trefil
AISI 316L stainless steel (SS) is one of the extensively used biomaterials to produce implants and medical devices. It provides a low-cost solution with ample mechanical properties, corrosion resistance, and biocompatibility compared to its counterpart materials. However, the implants made of this material are subjected to a short life span in human physiological conditions leading to the leaching of metal ions, thus limiting its use as a biomaterial. In this research, the addition of boron, titanium, and niobium with varying concentrations in the SS matrix has been explored. This paper explores the impact of material composition on modified SS alloy’s physical and mechanical properties. The study’s outcomes specify that the microhardness increases for all the alloy compositions, with a maximum increase of 64.68% for the 2 wt.% niobium added SS alloy. On the other hand, the tensile strength decreased to 297.40 MPa for the alloy containing 0.25 wt.% boron and 2 wt.% titanium additions compared to a tensile strength of 572.50 MPa for pure SS. The compression strength increased from 776 MPa for pure SS to 1408 MPa for the alloy containing niobium and titanium additions in equal concentrations.

17 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
ŠMŠárka Michenková
Šárka Michenková
LPLeopold Pleva
Leopold Pleva
JKJan Koutecký
Jan Koutecký
JFJiri Fries
Jiri Fries
Jiri PokornyJiri Pokorny
Jiri Pokorny
This article deals with a new original analytical solution of deformation, force and stress states in wood screw joints up to the limit values of pulling out/breaking the screw. The screws are under tension. The wood-to-screw interaction is effectively simplified by introducing several physical model variants using a tangential elastic non-linear foundation. The experimental verification of the proposed models using pull-out tests (i.e., pulling out screws from dry spruce wood in laboratory conditions) confirms the correctness of the proposed models of the elastic linear/non-linear foundation. The validity of the model is also analytically and experimentally verified in the biomechanical model of pulling out screws from the femur of a bovine/human cadaver, which confirms and expands the validity of newly designed screw joint models outside the timber structure area.

25 July 2025 in Materials Science and Technology
Verified
Journal Article
Open access
MMMartin Matušů
Martin Matušů
Jan PapugaJan Papuga
Jan Papuga
KTKarel Trojan
Karel Trojan
ATAntonín Trefil
Antonín Trefil
AZAlaitz Zabala
Alaitz Zabala
PDPetr David
Petr David
This study investigates how machining parameters affect surface integrity and fatigue performance in 42CrMo4 + QT steel. Nine turning setups were tested to evaluate surface roughness, residual stresses, and fatigue strength. Fatigue testing under fully reversed loading (R = –1) at ∼150 Hz revealed that the best fatigue performance occurred in the setup with a cutting speed of 100 m/min, feed rate of 0.1 mm/min, tool nose radius of 0.4 mm, 0.3 mm total finishing depth (over three cuts), and coolant applied. Cutting speed showed the clearest benefit, while other parameters had less predictable effects. Surface roughness did not consistently correlate with fatigue life. Overall, selected machining parameters strongly influence fatigue behavior, though roughness and residual stresses alone do not fully explain the performance trends observed.

25 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
Tomáš HaloTomáš Halo
Tomáš Halo
DČDaniel ČEPICA
Daniel ČEPICA
VMVojtěch Machalla
Vojtěch Machalla
KVKateřina Vlčková
Kateřina Vlčková
JHJosef Hlinka
Josef Hlinka
This article focuses on a type of surgical implant used in orthopaedics and traumatology—cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.

1 January 2019
Verified
Conference Paper
Closed access
TZTomas Zlamal
Tomas Zlamal
ŠMŠárka Malotová
Šárka Malotová
TSTomáš Szotkowski
Tomáš Szotkowski
OVOndřej VORTEL
Ondřej VORTEL
ATAntonín Trefil
Antonín Trefil

1 April 2026 in Strojnícky časopis - Journal of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
ASAnilraj Sudhakar
Anilraj Sudhakar
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
LKLucie Krejčí
Lucie Krejčí
ATAntonín Trefil
Antonín Trefil
DČDaniel ČEPICA
Daniel ČEPICA
The paper focuses on developing a simple symmetric planar truss structure that could be effectively used to understand and study nonlinearities in large structures. A simple two-member truss model was defined and used for the study. A simple analytical model was derived using the theories of first and second order, which were then solved using the numerical formulations. To validate the model, an experimental setup was created and mounted on a tensile testing machine to apply required loads on the system. The results obtained from the test are used to validate the numerical model. Different parametric studies were conducted using the validated model to further understand the effects of the different variables on the model’s behaviour.