He Zhang

Prof. Dr. He Zhang

School of Information Science and Engineering, Shenyang University of Technology
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
He ZhangHe Zhang
He Zhang
XLXiaowei Liu
Xiaowei Liu
LTLi Tian
Li Tian
XHXiaowei Han
Xiaowei Han
In this paper, we proposed a novel bonding technology to fabricate a microfluidic device based on Poly(methyl methacrylate) (PMMA). The method, which used chloroform and ethanol as miscible bonding solvent, can complete complex structures rapid assembly (10 min) at 40°C. A bonding strength of 267.5 N/cm2 can be achieved, while the micro channel deformation was less than 7.26%. Then we utilized this method to produce a three layers micro mixer, which included a T-shaped inlet channel and six H-shaped mixing units. Numerical simulation indicated that, the well mixing length of the mixer was only about 6 mm when Re = 10. Finally, fluorescence microscopy was used to verify mixer performance. The method provided the potential for mass production of multilayer rigid polymer microfluidic devices.

10 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
He ZhangHe Zhang
He Zhang
SYShuang Yang
Shuang Yang
JZJian Zeng
Jian Zeng
XLXin Li
Xin Li
RCRongyan Chuai
Rongyan Chuai
When the free end of a microcantilever is modified by a genetic probe, this sensor can be used for a wider range of applications, such as for chemical analysis, biological testing, pharmaceutical screening, and environmental monitoring. In this paper, to clarify the preparation and detection process of a microcantilever sensor with genetic probe modification, the core procedures, such as probe immobilization, complementary hybridization, and signal extraction and processing, are combined and compared. Then, to reveal the microcantilever’s detection mechanism and analysis, the influencing factors of testing results, the theoretical research, including the deflection principle, the establishment and verification of a detection model, as well as environmental influencing factors are summarized. Next, to demonstrate the application results of the genetic-probe-modified sensors, based on the classification of detection targets, the application status of other substances except nucleic acid, virus, bacteria and cells is not introduced. Finally, by enumerating the application results of a genetic-probe-modified microcantilever combined with a microfluidic chip, the future development direction of this technology is surveyed. It is hoped that this review will contribute to the future design of a genetic-probe-modified microcantilever, with further exploration of the sensitive mechanism, optimization of the design and processing methods, expansion of the application fields, and promotion of practical application.

14 June 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
He ZhangHe Zhang
He Zhang
XLXin Li
Xin Li
RCRongyan Chuai
Rongyan Chuai
YZYingjie Zhang
Yingjie Zhang
To improve the efficiency of mixing under laminar flow with a low Reynolds number (Re), a novel three-dimensional Horseshoe Transformation (3D HT) was proposed as the basis for the design of a micromixer. Compared with the classical HT, the Lyapunov exponent of the 3D HT, which was calculated based on a symbolic dynamic system, proved the chaotic enhancement. Based on the 3D HT, a micromixer with a mixing length of 12 mm containing six mixing units was obtained by sequentially applying “squeeze”, “stretch”, “twice fold”, “inverse transformation”, and “intersection” operations. Numerical simulation and Peclet Number (Pe) calculations indicated that when the squeeze amplitude 0 < α < 1/2, 0 < β < 1/2, the stretch amplitude γ > 4, and Re ≥ 1, the mass transfer in the mixer was dominated by convective diffusion induced by chaotic flow. When Re = 10, at the outlet of the mixing chamber, the simulated mixing index was 96.4%, which was far less than the value at Re = 0.1 (σ = 0.041). Microscope images of the mixing chamber and the curve trend of pH buffer solutions obtained from a mixing experiment were both consistent with the results of the simulation. When Re = 10, the average mixing index of the pH buffer solutions was 91.75%, which proved the excellent mixing efficiency of the mixer based on the 3D HT.

7 August 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
MWMeile Wu
Meile Wu
ZWZhixin Wu
Zhixin Wu
HCHefei Chen
Hefei Chen
WZWu Zhanyu
Wu Zhanyu
PZPeng Zhang
Peng Zhang
XJXiaoshi Jin
Xiaoshi Jin
Humidity and oxygen have significant impacts on the accuracy of hydrogen detection, especially for metal oxide semiconductor sensors at room temperature. Addressing this challenge, this study employs a screen-printed 1 × 2 resistive sensor array made from an identical 1 wt.% platinum-modified tin oxide nanoparticle material. Fabrication variability between the two sensing elements was intentionally leveraged to enhance array output differentiation and information content. Systematic hydrogen-sensing tests were conducted on the array under diverse oxygen and moisture conditions. Three distinct feature types—the steady-state value, resistance change, and area under the curve—were extracted from the output of each array element. These features, integrated with their quotient, formed a nine-feature vector matrix. A multiple linear regression model based on this array output was developed and validated for hydrogen prediction, achieving a coefficient of determination of 0.95, a mean absolute error of 125 ppm, and a mean relative standard deviation of 7.07%. The combined information of the array provided significantly more stable and precise hydrogen concentration predictions than linear or nonlinear models based on individual sensor features. This approach offers a promising path for mass-producing highly interference-resistant, precise, and stable room-temperature hydrogen sensor arrays.

7 March 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
He ZhangHe Zhang
He Zhang
RCRongyan Chuai
Rongyan Chuai
XLXin Li
Xin Li
BZBing Zhang
Bing Zhang
To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1) using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2) controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height), and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg2+ and Pb2+ in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology.

27 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
He ZhangHe Zhang
He Zhang
SYShuang Yang
Shuang Yang
RCRongyan Chuai
Rongyan Chuai
XLXin Li
Xin Li
XMXinyu Mu
Xinyu Mu
In order to investigate the influence of the unit junction on the micromixer performance, a repetitive structure micromixer with a total length of 12.3 mm was proposed. This micromixer consists of a T-shape inlet channel and six cubic mixing units, as well as junctions between them. Numerical simulations show that, when the junctions are all located at the geometric center of the cubic mixing unit, the outlet mixing index is 72.12%. At the same flow velocity, the best mixing index achieved 97.15% and was increased by 34.68% when the junctions were located at different corners of the cubic mixing unit. The improvement in the mixing index illustrated that the non-equilibrium vortexes generated by changing the junction location to utilize the restricted diffusion by the mixing unit’s side wall could promote mixing. Visual tests of the micromixer chip prepared by 3D printing were consistent with the simulation results, also indicating that the junction location had a significant influence on the mixer’s performance. This article provides a new idea for optimizing the structural design and improving the performance of micromixers.