Industrial activities produce a variety of pollutants that may not be easily treated using centralized wastewater treatment systems based on a single treatment unit. The variability of the pollutants brings the importance of industrial-specific integrated wastewater treatment plants such as integrated membrane filtration systems. However, the performance of a membrane filtration process can be highly affected by the presence of high amounts of suspended particles in the raw wastewater. Therefore, proper selection of a pre-treatment unit prior to a membrane filtration wastewater treatment system is a key aspect of its performance. This study investigated the performance of an integrated membrane filtration treatment system connected to an electrochemical process (pre-treatment) on the purification of a poultry slaughterhouse wastewater toward achieving a high-quality effluent. The industrial-scale treatment plant installed at the Izhevsk Production Corporative (PC) poultry farm in Kazakhstan is composed of an electrochemical, ultrafiltration (UF), and reverse osmosis (RO) as the main treatment units. From the analysis results, the electrochemical pre-treatment unit was observed to be highly effective for the removal of some physicochemical parameters such as turbidity, color, total suspended solids, total iron, aluminum, chemical oxygen demand, and biochemical oxygen demand; with removal efficiency ranging from 71 to 85%. The low removal efficiency of the pre-treatment system was also observed from free and total chlorine, nitrites, nitrates, phosphates, and ammonium nitrogen; with removal efficiency ranging from 4 to 45%. While in general, the overall treatment train was observed to be highly efficient for some physicochemical parameters such as turbidity, color, total suspended solids, as well as chemical and biochemical oxygen demand; maintaining almost 100% removal efficiency throughout the study period. Also, the high removal efficiency of the electrochemical pre-treatment processes led to a relatively low rate of cake formation on the membrane filters.
Understanding the efficiency of different wastewater treatment technologies tested under real conditions is essential for successful decision making by engineers and managers. In this study, real poultry slaughterhouse wastewater coming from defeathering, cooling, and evisceration processes was treated using a lab-scale electrochemical process by use of iron-iron (Fe-Fe), iron-graphite (Fe-Gr) and aluminum-graphite (Al-Gr) electrode combinations. A water quality index (WQI) was developed and used as a tool for evaluating and classifying the effectiveness of different electrode combinations. The Al-Gr electrode combination showed an impressive performance achieving an “excellent” status for all of the three studied sources of wastewater with a WQI ranging from 13 to 34. The Fe-Gr electrode combination showed an “excellent” status performance for the wastewater from the cooling process as classified by the WQI and “good water” class for the defeathering and evisceration processes. The lower performance, which was highly affected by the increase in turbidity, was observed for the Fe-Fe electrode combination with a “poor water” status for the wastewater coming from defeathering and cooling processes and “good water” status for evisceration process.
The efficiency of a wastewater treatment process may be affected by several factors including the scale at which the system is operating. This study aimed at investigating the influence of scale on a poultry slaughterhouse wastewater treatment process. The process is comprised of several units including electrolysis, membrane filtration, and ultraviolet irradiation. The results of the industrial-scale wastewater treatment plant of the Izevski poultry farm slaughterhouse in Kazakhstan were compared with those of a lab-scale wastewater treatment process under the same conditions. The traditional and water quality index (WQI) approaches were used to present the results and the drinking water quality standards of Kazakhstan were used as a reference. The industrial and lab-scale plants showed high purification efficiency for most of the studied water quality parameters. The comparative analysis based on the WQI showed that the industrial-scale wastewater treatment plant outperforms the lab-scale wastewater treatment process.
Despite the potential applicability of the combination between aluminium (anode) and graphite or titanium (cathode) for poultry slaughterhouse wastewater treatment, their technical and economic feasibilities have not been comprehensively captured. In this study, aluminium (anode) and graphite and titanium as cathode electrode materials were investigated and compared in terms of their performance on poultry slaughterhouse wastewater treatment. The wastewater samples collected from the Izhevsk Production Corporative (PC) poultry farm in Kazakhstan were treated using a lab-based electrochemical treatment plant and then analyzed after every 20 and 40 min of the treatment processes. Cost analysis for both electrode combinations was also performed. From the analysis results, the aluminium–graphite electrode combination achieved high removal efficiency from turbidity, color, nitrite, phosphates, and chemical oxygen demand, with removal efficiency ranging from 72% to 98% after 20 min, as well as 88% to 100% after 40 min. A similar phenomenon was also observed from the aluminium–titanium electrode combination, with high removal efficiency achieved from turbidity, color, total suspended solids, nitrite, phosphates, and chemical oxygen demand, ranging from 81% to 100% after 20 min as well as from 91% to 100% after 40 min. This means the treatment performances for both aluminium–graphite and aluminium–titanium electrode combinations were highly affected by the contact time. The general performance in terms of removal efficiency indicates that the aluminium–titanium electrode combination outperformed the aluminium–graphite electrode combination. However, the inert character of the graphite electrode led to a positive impact on the total operating cost. Therefore, the aluminium–graphite electrode combination was observed to be cheaper than the aluminium–titanium electrode combination in terms of the operating cost.
Zeolite materials are among the relatively cheap and readily available materials for wastewater treatment. However, the performance of zeolite-based systems can be highly affected by the material properties. In this study, the treatment system based on natural zeolite materials from Chankanai mines in Kazakhstan was compared with a synthetic zeolite treatment system for the purification of groundwater. Water quality indices were also developed from a set of selected water quality parameters to further assess the state of water quality of raw groundwater and the effluents treated with natural and synthetic zeolite. The lowest removal efficiency of natural zeolite (30%) was observed with zinc, while the lowest removal efficiency (36%) of synthetic zeolite was observed with arsenic. With turbidity and beryllium, we observed the maximum removal efficiency (100%) of natural zeolite, whereas with turbidity, we observed the highest removal efficiency (100%) of synthetic zeolite. When the groundwater samples were put through the natural zeolite treatment system, removal efficiency of 50% and above was obtained with 27 (79.4%) out of the 34 water quality parameters examined. On the other hand, when the groundwater samples were put through the synthetic zeolite treatment system, more than 50% removal efficiency was attained with 30 (88.2%) out of the 34 water quality parameters studied. The aggregated water quality index of raw groundwater was 3278.24, falling in the “water unsuitable for drinking” category. The effluent treated with natural zeolite generated 144.82 as a water quality index, falling in the “poor water” quality category. Synthetic zeolite generated 94.79 as a water quality index, falling in the “good water” quality category. Across the board, it was shown that the synthetic zeolite treatment system outperformed the natural zeolite treatment system according to a number of water quality parameters. The findings of this study offer substantial knowledge that can be used to develop more efficient groundwater treatment technologies.
Poultry slaughterhouse wastewater is characterized by high pollution strength, making its treatment before discharge or recycling of great importance. This study investigated the potential influence of mixing ratios on the treatability of poultry slaughterhouse wastewater under three different mixing ratios; 20:80, 50:50, and 80:20 of defeathering and cooling sources, respectively. Wastewater samples were collected from the Izhevski production corporate (PC) poultry farm located in the Akmola region, Kazakhstan. The lab-scale treatment plant, designed to simulate the industrial-scale treatment plant of the poultry farm, consists of electrolysis, membrane filtration, and ultraviolet disinfection as the main units. The general design purpose of the Izhevski PC treatment plant is to treat about 1.25 m3/h (51.72%) of the total wastewater generated from the defeathering and cooling sections of the slaughterhouse to a recyclable degree. Water quality indices (WQIs) were developed for each of the studied mixing ratios. A comparative analysis was also done with drinking water quality standards set by the World Health Organization (WHO), as well as the government of Kazakhstan. From the analysis results, the defeathering raw wastewater was generally higher in pollution strength than the cooling wastewater. It was also observed that the increase in the ratio of defeathering wastewater reduced treatment efficiency for some physicochemical parameters such as turbidity, total suspended solids (TSS), color, biochemical oxygen demand (BOD), as well as chemical oxygen demand (COD). However, 100% removal efficiency was achieved for the microbial parameters for all the three studied ratios. Based on the computed WQIs, the highest-quality effluent was achieved from the 20:80 (defeathering:cooling) mixing ratio. However, with the fact that all the three mixing ratios produced “excellent” status, the 80:20 (defeathering:cooling) mixing ratio stands to be an ideal option. The selection of 80:20 mixing ratio has the potential to reduce the pollution load in the wastewater discharged to the sewerage system, while achieving high-quality effluent for recycling in the cooling processes of the slaughterhouse.