Ningning Liang

Dr. Ningning Liang

School of Materials Science and Engineering, Nanjing University of Science and Technology

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Entropy
Verified
Journal Article
Open access
PDF file
Ningning LiangNingning Liang
Ningning Liang
XWXiang Wang
Xiang Wang
YCYang Cao
Yang Cao
YLYusheng Li
Yusheng Li
YZYuntian Zhu
Yuntian Zhu
Yonghao ZhaoYonghao Zhao
Yonghao Zhao
The surface nano-crystallization of Ni2FeCoMo0.5V0.2 medium-entropy alloy was realized by rotationally accelerated shot peening (RASP). The average grain size at the surface layer is ~37 nm, and the nano-grained layer is as thin as ~20 μm. Transmission electron microscopy analysis revealed that deformation twinning and dislocation activities are responsible for the effective grain refinement of the high-entropy alloy. In order to reveal the effectiveness of surface nano-crystallization on the Ni2FeCoMo0.5V0.2 medium-entropy alloy, a common model material, Ni, is used as a reference. Under the same shot peening condition, the surface layer of Ni could only be refined to an average grain size of ~234 nm. An ultrafine grained surface layer is less effective in absorbing strain energy than a nano-grain layer. Thus, grain refinement could be realized at a depth up to 70 μm in the Ni sample.

5 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
ZZzhou zhikai
zhou zhikai
DSDan SONG
Dan SONG
Ningning LiangNingning Liang
Ningning Liang
HJHaiyang Jiang
Haiyang Jiang
BGBo Gao
Bo Gao
XMXiaolong Ma
Xiaolong Ma
In this paper, the effect of the equal-channel-angular-pressed (ECAPed) substrate on the coating formation and anticorrosion performance of the anodized Al–11Si alloy was systematically investigated. The ECAP process dramatically refines both Al and Si phases of the alloy. The parallel anodizing circuit is designed to enable a comparative study of anodizing process between the cast and the ECAPed alloys by tracking their respective anodizing current quota. The optimum coatings of both alloys were obtained after anodization for 30 min. The ECAPed alloy attained a thicker, more compact, and more uniform coating. Energetic crystal defects in the fine Al grains of the ECAPed substrate promote the anodizing reaction and lead to the thicker coating. Fragmented and uniformly distributed fine Si particles in the ECAPed alloy effectively suppress the coating cracks, enhancing the compactness of the coating. Overall, the ECAP-coated sample exhibits the best anticorrosion performance, which is evidenced by the concurrently enhanced prevention of coating and improved corrosion resistance of the substrate.

15 January 2023 in Coatings
Verified
Journal Article
Open access
PDF file
WLWeilin Liu
Weilin Liu
QWQiuyue Wang
Qiuyue Wang
GZGongnian Zou
Gongnian Zou
EKEdwin Eyram Klu
Edwin Eyram Klu
ZAZhiyong Ai
Zhiyong Ai
DSDan SONG
Dan SONG
Surface nanocrystallization (SNC) modification can be used to realize the high-efficiency derusting of rusted Cr-alloyed rebar and obtain nanostructured grains on the surface of the rebar. The corrosion resistance performance of SNC rebar in a simulated Cl--containing concrete pore solution was evaluated on the basis of electrochemical experiments. Potentiodynamic polarization testing showed that the passivation current density of the SNC rebar was about 18% of that of the rusted rebar. The structural composition of the passivation film of the SNC rebar in a concrete environment was studied using a novel characterization method, namely XPS deep sputtering, which confirmed that it had higher concentrations of Cr/Fe oxide and hydroxide, and therefore exhibited an enhanced degree of oxidation. Moreover, scanning electron microscopy and transmission electron microscopy were employed to investigate the microstructural characteristics of the SNC rebar, which was characterized by nanostructured grains with grain sizes ranging from 250 nm to 300 nm and which contained massive high-energy crystal defects, thereby promoting the film-forming reaction of Cr/Fe elements. The results of XPS depth analysis and microstructure characterization demonstrated that the SNC rebar exhibited excellent passivation performance in the concrete environment. These findings offer a new perspective on enhancing the passivation performance and chloride resistance of alloyed rebar, and provide guidance on the implementation of SNC rebar in actual engineering applications.

28 February 2020 in Coatings
Verified
Journal Article
Open access
PDF file
GWGuowei Wang
Guowei Wang
DSDan SONG
Dan SONG
ZZzhou zhikai
zhou zhikai
EKEdwin Eyram Klu
Edwin Eyram Klu
YLYi Liu
Yi Liu
AMAibin Ma
Aibin Ma
This work analyzes the effects of ultrafine aluminum (Al) grains on the anodizing coating reaction and anticorrosion performance of anodized industrial pure Al. Equal-channel angular pressing (ECAP) was applied to cast pure Al continuously for 16 passes at room temperature, and its average grain size was dramatically refined to about 1.5 μm. The ultrafine-grain (UFG) pure Al was further anodized with a cast sample via a parallel anodizing circuit at a constant total input current. Benefited by the higher volume fraction of grain boundaries and higher internal energy of the UFG substrate, the anodizing process of the ECAP-processed pure Al was significantly accelerated, showing a more intense initial anodizing reaction, a faster initial coating thickening, and much earlier porous-layer formation compared to the cast sample. As the anodizing reaction continued, the newly formed thicker coating of the ECAP-coated sample significantly hindered the diffusion process, weakening the thermodynamic advantage and decreasing the anodizing current of the ECAP-processed sample. During the entire anodizing duration, the ECAP-processed pure Al experienced gradually decreased anodizing current, while the cast sample experienced increased anodizing current. Because of the more total reaction, the ECAP-coated sample always maintained a relatively thicker coating and better anticorrosion performance during the entire anodizing duration.