Ritthichai Ratchapan

Dr. Ritthichai Ratchapan

Electrical Engineering, Rajamangala University of Technology, Thanyaburi, Thailand
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
Phuwanat MarksanPhuwanat Marksan
Phuwanat Marksan
KBKrittidet Buayai
Krittidet Buayai
Ritthichai RatchapanRitthichai Ratchapan
Ritthichai Ratchapan
WSWutthichai Sa-nga-ngam
Wutthichai Sa-nga-ngam
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Active distribution systems (ADS) are increasingly strained by rising energy demand and the widespread deployment of distributed energy resources (DERs) and electric vehicle charging stations (EVCS), which intensify voltage deviations, power losses, and peak demand fluctuations. This study develops a coordinated optimization framework for Mobile Battery Energy Storage Systems (MBESS) and Dynamic Feeder Reconfiguration (DFR) to enhance network performance across technical, economic, and environmental dimensions. A Non-dominated Sorting Genetic Algorithm III (NSGA-III) is employed to minimize six objectives the active and reactive power losses, voltage deviation index (VDI), voltage stability index (FVSI), operating cost, and CO2 emissions while explicitly modeling the MBESS transportation constraints such as energy consumption and single-trip mobility within coupled IEEE 33-bus and 33-node transport networks, which provide realistic mobility modeling of energy storage operations. The Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) is applied to select compromise solutions from Pareto fronts. Simulation results across six scenarios show that the coordinated MBESS–DFR operation reduces power losses by 27.8–30.1%, improves the VDI by 40.5–43.2%, and enhances the FVSI by 2.3–2.4%, maintaining all bus voltages within 0.95–1.05 p.u. with minimal cost (0.26–0.27%) and emission variations (0.31–0.71%). The MBESS alone provided limited benefits (5–12%), confirming that coordination is essential for improving efficiency, voltage regulation, and overall system sustainability in renewable-rich distribution networks.

10 March 2021
Verified
Conference Paper
Closed access
Ritthichai RatchapanRitthichai Ratchapan
Ritthichai Ratchapan
YKYuttana Kongjeen
Yuttana Kongjeen
BPBoonyang Plangklang
Boonyang Plangklang
This paper presents the ampacity analysis of low voltage underground cables in the different conduits using the thermal finite element method. The conduit consists of a steel conduit, HDPE conduit, RTRC conduit, and PVC conduit. Underground conduits are installed below ground level 0.3 - 0.75 m. that are buried in the sand. The highest temperature is considered in Bangkok at 40.8°C. The results showed that the underground cable ampacity in various conduits that can be carried high ampacity were as follows: steel conduit, RTRC conduit, HDPE conduit, and PVC conduit, respectively. While the ampacity of underground cables decreased when the depth level of conduits was increased. On the other hand, the ampacity of underground cables increased when the ground temperature was decreased. Furthermore, this study revealed the limits and the environment that impact the underground cable ampacity and the need to find the optimal conditions for improving and following the installation standard regulation.

9 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
PPPongsuk Pilalum
Pongsuk Pilalum
SDSaksit Deeum
Saksit Deeum
KSKittiwong Suthamno
Kittiwong Suthamno
TKThongchai Klayklueng
Thongchai Klayklueng
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
This study presents a comprehensive multi-objective optimization framework for optimal placement and sizing of distributed generation (DG) units in electric bus (E-bus) transit systems integrated with a high-power flash charging infrastructure. An enhanced Multi-Objective Grey Wolf Optimizer (MOGWO), utilizing Euclidean distance-based Pareto ranking, is developed to minimize power loss, voltage deviation, and voltage violations. The framework incorporates realistic E-bus operation characteristics, including a 31-stop, 62 km route, 600 kW pantograph flash chargers, and dynamic load profiles over a 90 min simulation period. Statistical evaluation on IEEE 33-bus and 69-bus distribution networks demonstrates that MOGWO consistently outperforms MOPSO and NSGA-II across all DG deployment scenarios. In the three-DG configuration, MOGWO achieved minimum power losses of 0.0279 MW and 0.0179 MW, and voltage deviations of 0.1313 and 0.1362 in the 33-bus and 69-bus systems, respectively, while eliminating voltage violations. The proposed method also demonstrated superior solution quality with low variance and faster convergence, requiring under 7 h of computation on average. A five-method compromise solution strategy, including TOPSIS and Lp-metric, enabled transparent and robust decision-making. The findings confirm the proposed framework’s effectiveness and scalability for enhancing distribution system performance under the demands of electric transit electrification and smart grid integration.

28 January 2024 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
Ritthichai RatchapanRitthichai Ratchapan
Ritthichai Ratchapan
SKSomchai Kriprab
Somchai Kriprab
SMSupapradit Marsong
Supapradit Marsong
BPBoonyang Plangklang
Boonyang Plangklang
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
This study aimed to evaluate the ampacity and costs of different high voltage underground cable methods (cylindrical duct bank vs. square tunnel). The standards of Metropolitan Electricity Authority (MEA) of Thailand innovative approach to reduce road impact were used. Simulations for 115 kV cables showed that the maximum ampacity for cylindrical duct bank method was 523 A (flooding), and 509 A (non-flooding) while that of the square tunnel method was 445 A (flooding), and 405 A (non-flooding). Costs analysis were $573,446 per circuit for the cylindrical duct bank method and $404,363 per circuit for the square tunnel method
1

4 June 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
OAOluwaseun Olanrewaju Akinte
Oluwaseun Olanrewaju Akinte
Ritthichai RatchapanRitthichai Ratchapan
Ritthichai Ratchapan
Sarun NakthanomSarun Nakthanom
Sarun Nakthanom
KPKrisada Prompinit
Krisada Prompinit
Boonyang PlangklangBoonyang Plangklang
Boonyang Plangklang
This study examined a proposed system integrating waste power plants, a utility grid, and battery technologies to optimize energy operations for the On-nut community in Bangkok. The system was modeled through experimental, mathematical, and schematic approaches to identify the most efficient energy generation and cost management strategies utilizing lithium, flow, and zinc bromide batteries. This was achieved by employing industrial smart grid analysis, closed-loop algorithms, and feedback control systems to manage energy flow econometrics through switching operations, thereby maximizing electric cost efficiency and network service from the integrated system architectures (grid/lithium/biogas, grid/flow/biogas, and grid/zinc bromide/biogas systems). The proposed configuration of the biogas generator/grid/lithium-ion storage network demonstrated the highest technical efficiency in energy purchases, totaling 239,764 kWh, with energy sales to the grid amounting to 1,959,426 kWh and the lowest net energy purchase from the grid at 1,719,661 kWh. Conversely, the biogas generator/grid/zinc bromide storage configuration achieved the most economical network, reflected in an overall current cost of USD 8,647,863.00, an operating cost of USD 143,974.00, an investment return rate of 17.00%, an internal return rate of 20.30%, and a payback period of 4.83 years. The biogas generator/grid/zinc bromide network exhibited the highest performance ratio at 80.55%, surpassing the flow battery at 79.65% and lithium-ion at 78.89% in terms of energetic configurations.

9 March 2022
Verified
Conference Paper
Closed access
SKSomchai Kraiprab
Somchai Kraiprab
Ritthichai RatchapanRitthichai Ratchapan
Ritthichai Ratchapan
BPBoonyang Plangklang
Boonyang Plangklang
RKRungphet Kongnok
Rungphet Kongnok
YKYuttana Kongjeen
Yuttana Kongjeen
KKKaan Kerdchuen
Kaan Kerdchuen
This paper presents a design of a PV system for a primary distribution system under loss and voltage drop control based on ETAP program. The research area is selected within Rajamangala University of Technology Thanyaburi (RMUTT), Thailand. The Power System Simulator (ETAP) is used to design a primary distribution system simulation and PV installed of the RMUTT electrical system. The simulation results by comparing the loss and voltage drop from the based case and PV system installed of 900 kWp can be presented by reducing the grid’s electrical power loss and voltage drop.