Hung-Chun Li

Hung-Chun Li

Auto-generated profile, based on publicly available information

Hung-Chun Li

Zhuhai UM Science and Technology Research Institute-Lingyange Semiconductor Incorporated Joint Laboratory, Zhuhai, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2025 in IEEE Transactions on Network Science and Engineering
Verified
Journal Article
Closed access
ZWZhijiong Wang
Zhijiong Wang
AZAnguo Zhang
Anguo Zhang
HLHung Chun Li
Hung Chun Li
YYYadong Yin
Yadong Yin
Wei ChenWei Chen
Wei Chen
Sio Hang PunSio Hang Pun
Sio Hang Pun
People's increasing demand for high-quality network services has prompted the continuous attention and development of network traffic classification (NTC). In recent years, deep flow inspection (DFI) is considered to be the most effective and promising method to solve the NTC. However, DFI still cannot effectively address the problem of changes in flow characteristics of complex packet flows and the discovery of new traffic categories. In this paper, we propose a metric learning based deep learning solution with feature compressor, named deep flow embedding (DFE). The feature compressor is used to compress the feature information transmitted layer by layer in DL backbone while maintaining the computational accuracy, so that the backbone can remove as much noise, redundancy, and other irrelevant information from the input data as possible, and achieve more robust feature extraction of network traffic flow. The deep learning (DL) backbone generates an embedding vector for each network packet flow. Then the embedding vector is compared with the vector template preset for each traffic type in the template library to determine the category of the packet flow. Experimental results verify that our method is more effective than the traditional DFI methods in overcoming the problems of flow characteristics variation and new category discovery.

10 February 2025 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
LYLiyuan Yang
Liyuan Yang
HLHung Chun Li
Hung Chun Li
AZAnguo Zhang
Anguo Zhang
CMChaoxu Mu
Chaoxu Mu
YSYongduan Song
Yongduan Song
In recent years, proton exchange membrane fuel cell (PEMFC) systems have emerged as a promising sustainable energy source, recognized for their high power density and zero-emission characteristics. However, these systems are highly sensitive to variations in the oxygen-excess ratio (OER), which directly impacts their efficiency and lifespan. Controlling the OER presents significant challenges due to the system’s inherent nonlinearities, model uncertainties, and susceptibility to external disturbances. To address these challenges, we propose an adaptive dynamic surface control with a disturbance observer (ADSCDOB) method to mitigate adverse effects and enhance control accuracy. The disturbance observer is designed using a nonlinear approach to effectively estimate uncertainties and external disturbances. The ADSCDOB method integrates adaptive dynamic surface control technology, enabling robust control while overcoming the "explosion of complexity" problem typical of traditional backstepping methods. The stability of the closed-loop system is rigorously established through theoretical analysis. Simulations validate the effectiveness of the ADSCDOB method, demonstrating its rapid response, minimal error, and robust stability across various operating conditions.

1 March 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
XTXielan Tang
Xielan Tang
BZBin Zhang
Bin Zhang
YLYamei Li
Yamei Li
MGMing Guan
Ming Guan
Nian XiongNian Xiong
Nian Xiong
MVMang.I Vai
Mang.I Vai
The electrocardiogram (ECG) has emerged as a viable alternative to polysomnography (PSG) for the detection of obstructive sleep apnea (OSA). Given the limited feature information of ECG signals in a single domain, this study proposes an adaptive threshold denoising synchrosqueezed wavelet transform (ADSWT) algorithm to extract high-resolution time-frequency domain features of ECG signals. The ADSWT algorithm enhances the time-frequency resolution, enabling better extraction of key features while minimizing noise interference, and generates an ECG scalogram as input for the network. Additionally, we propose a hybrid residual neural network (HRN-Net) for the automatic classification of OSA. The HRN-Net is designed with a dynamic feature extraction module to parse complex local features and enhance the network's generalization capability, as well as a dependency modeling module to capture the relationships between global contextual information for better understanding and interpretation of the ECG signals. All-night PSG recordings from both public and private datasets are used to validate the proposed framework. The results show that the framework achieves an accuracy of 0.942, a sensitivity of 0.926, a specificity of 0.959, and an F1 score of 0.942 on the public dataset, and an accuracy of 0.946, a sensitivity of 0.921, a specificity of 0.972, and an F1 score of 0.945 on the private dataset. These results indicate that the proposed framework offers high accuracy in automatic OSA classification and has significant potential to aid clinical decision-making.

22 November 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HWHan Wang
Han Wang
DLDongming Li
Dongming Li
MVMang.I Vai
Mang.I Vai
Sio Hang PunSio Hang Pun
Sio Hang Pun
JYJiejie Yang
Jiejie Yang
YueMing GaoYueMing Gao
YueMing Gao
Conductive Intracardiac Communication (CIC) uses cardiac tissue as a transmission medium for short-range wireless communication and is a potential method for enabling leadless multi-chamber pacing. However, the characterization of the intracardiac channel is significantly influenced by the experimental setup and conditions. The reported results in the literature vary depending on the measurement methods used, posing challenges in obtaining reliable channel characterization for CIC. In this paper, we aim to investigate the effects of different measurement devices and conditions on the intracardiac channel. By clarifying how impedance imbalance affects the gain measurement results, we design a weak-signal measurement circuit with high common-mode rejection. This new circuit provides a more accurate and effective gain measurement scheme for the CIC channel. An equivalent circuit model simulating cardiac biomechanical impedance is constructed to analyze how capacitive and resistive imbalances affect the gain measurement results. The effects of these imbalances are verified by intracardiac channel impedance imbalance experiments. A high common-mode rejection-high-resistance differential measurement circuit that can reduce the effects of capacitive and resistive imbalances simultaneously, is then designed to suppress the interference in the experiments. The results show that changes in the measurement equipment and isolation method lead to variations in the coupling circuit characteristics, causing differences of up to 16.65 dB in the measurement results. Experiments using the designed measurement circuits effectively mitigate interference from impedance imbalance on the measurement results. This study identifies the reasons behind the discrepancies in the experimental results of previous studies and provides a more reliable gain measurement scheme for CIC research.

14 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DLDongming Li
Dongming Li
ZWZhijiong Wang
Zhijiong Wang
HWHan Wang
Han Wang
Sio Hang PunSio Hang Pun
Sio Hang Pun
PMPeng Un Mak
Peng Un Mak
MVMang.I Vai
Mang.I Vai
Leadless pacemakers (LCPs) have emerged as a viable solution to mitigate the side effects associated with traditional pacing leads. Nevertheless, the absence of suitable intracardiac communication methods restricts most LCPs to single-chamber pacing. Galvanic conductive communication (GCC) offers a promising approach for achieving intracardiac communication in multi-chamber LCPs. However, impedance mismatch between the receiver and myocardium during the cardiac cycle can lead to a reduction in path gain, thereby affecting communication stability. This paper proposed a dynamic compensation method to reduce impedance mismatch and enhance communication stability. We developed a simplified LCP system with dynamic path gain compensation and validated it on an ex vivo porcine heart dynamic experimental platform. The results demonstrated a path gain improvement of 9.23 dB and a reduction in path gain variation from 3.95 dB to 0.3 dB. Additionally, the bit error rate (BER) decreased by over 50% across various transmission rates, with the most significant improvement observed at 5 kbps, where it decreased by 82.7%. These findings provide a high-reliability solution for intracardiac communication and establish a foundation for future multi-chamber sequential pacing applications in LCPs.

22 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LDLi Dongming
Li Dongming
JWJiamei Wang
Jiamei Wang
HWHan Wang
Han Wang
XHXiaojiang Huang
Xiaojiang Huang
JYJiejie Yang
Jiejie Yang
Sio Hang PunSio Hang Pun
Sio Hang Pun
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.