Wide bandgap (WBG) semiconductors are becoming more widely accepted for use in power electronics due to their superior electrical energy efficiencies and improved power densities. Although WBG cubic silicon carbide (3C-SiC) displays a modest bandgap compared to its commercial counterparts (4H-silicon carbide and gallium nitride), this material has excellent attributes as the WBG semiconductor of choice for low-resistance, reliable diode and MOS devices. At present the material remains firmly in the research domain due to numerous technological impediments that hamper its widespread adoption. The most obvious obstacle is defect-free 3C-SiC; presently, 3C-SiC bulk and heteroepitaxial (on-silicon) display high defect densities such as stacking faults and antiphase boundaries. Moreover, heteroepitaxy 3C-SiC-on-silicon means low temperature processing budgets are imposed upon the system (max. temperature limited to ~1400 °C) limiting selective doping realisation. This paper will give a brief overview of some of the scientific aspects associated with 3C-SiC processing technology in addition to focussing on the latest state of the art results. A particular focus will be placed upon key process steps such as Schottky and ohmic contacts, ion implantation and MOS processing including reliability. Finally, the paper will discuss some device prototypes (diodes and MOSFET) and draw conclusions around the prospects for 3C-SiC devices based upon the processing technology presented.
Affinity biosensors based on graphene field-effect transistor (GFET) or resistor designs require the utilization of graphene’s exceptional electrical properties. Therefore, it is critical when designing these sensors, that the electrical properties of graphene are maintained throughout the functionalization process. To that end, non-covalent functionalization may be preferred over covalent modification. Drop-cast 1,5-diaminonaphthalene (DAN) was investigated as a quick and simple method for the non-covalent amine functionalization of carbon-based surfaces such as graphene, for use in biosensor development. In this work, multiple graphene surfaces were functionalized with DAN via a drop-cast method, leading to amine moieties, available for subsequent attachment to receptor molecules. Successful modification of graphene with DAN via a drop-cast method was confirmed using X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and real-time resistance measurements. Successful attachment of receptor molecules also confirmed using the aforementioned techniques. Furthermore, an investigation into the effect of sequential wash steps which are required in biosensor manufacture, on the presence of the DAN layer, confirmed that the functional layer was not removed, even after multiple solvent exposures. Drop-cast DAN is thus, a viable fast and robust method for the amine functionalization of graphene surfaces for use in biosensor development.
21 September 2020 in IEEE Transactions on Electron Devices
β -Ga₂O₃ is one of the promising semiconductor materials that has been widely used in power electronics and ultraviolet (UV) detectors due to its wide bandgap and high sensitivity to UV light. Specifically, for the UV detection application, it has been reported that the photocurrent was in the scale of microamps (μA), which normally requires sophisticated signal processing units. In this work, a novel approach based upon coupling of two Schottky diodes is reported, leads to a substantial increase in photocurrent (~186 times) when benchmarked against a conventional planar UV photodiode. The detectivity and responsivity of the new device have also been significantly increased; the rectification ratio of this device was measured to be 1.7 x 10⁷ with ultralow dark current, when measured in the reverse bias. The results confirm that the approach of coupling two Schottky diodes has enormous potential for improving the optical performance of deep UV sensors.
18 May 2015 in Semiconductor Science and Technology
The application of electrical nanoprobes to measure and characterize nanomaterials has become widely spread. However, the formation of quality electrical contacts using metallic probes on nanostructures has not been directly assessed. We investigate here the electrical behaviour of non-lithographically formed contacts to ZnO nanowires (NWs) and develop a method to reproducibly form Ohmic contacts for accurate electrical measurement of the nanostructures. The contacting method used in this work relies on an electrical feedback mechanism to determine the point of contact to the individual NWs, ensuring minimal compressive strain at the contact. This developed method is compared with the standard tip deflection contacting technique and shows a significant improvement in reproducibility. The effect of excessive compressive strain at the contact was investigated, with a change from rectifying to ohmic I – V behaviour observed as compressive strain at the contact was increased, leading to irreversible changes to the electrical properties of the NW. This work provides an ideal method for forming reproducible non-lithographic nanocontacts to a multitude of nanomaterials.
This letter presents first-ever fabricated GaN split-current magnetic sensor device. Device operation and key manufacturing steps are also presented. The measured relative current sensitivity is constant at 14 % T -1 for wide mT range of the magnetic field. Constant sensitivity of a fabricated sensor can be attributed to device's 2DEG nature, i.e., its high electron concentration and mobility, and very small layer thickness.
31 July 2020 in The Journal of Physical Chemistry C