Jiangnan Liu

Jiangnan Liu

Auto-generated profile, based on publicly available information

Jiangnan Liu

Guangzhou Power Supply Bureau of Guangdong Power Grid Co., Ltd, Guangzhou, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XZXiaoyu Zhou
Xiaoyu Zhou
ZZZhiwen Zhang
Zhiwen Zhang
SDShoulong Dong
Shoulong Dong
LYliang yu
liang yu
JLJiangnan Liu
Jiangnan Liu
CYChenguo Yao
Chenguo Yao
In order to meet the requirements of high voltage, high power, and compactness for pulse generators used in the field of liquid food sterilization, an all-solid-state Marx generator based on a novel magnetic isolated drive is proposed. The drive circuit uses the magnetic core to transfer the control signal, which adopts core stacking and inverse paralleled secondary side winding. It only needs one drive signal to realize synchronous conduction of the main switch or bypass switch and the complementary conduction of both. The maximum pulse width of drive signal is not limited by the magnetic core saturation. The topology is simple, and the problem of high voltage isolated drive of Marx generator is solved. Based on the novel magnetic drive, a 31-module solid-state Marx generator is built and a prototype test is carried out. The test results show that the maximum instantaneous power of this generator is 1.3 MW (30 kV, 43 A) with a pulse width of 3–10 μ s and an adjustable repetition frequency of 0–1 kHz.

30 November 2020 in IEEE Access
Verified
Journal Article
Open access
JLJiangnan Liu
Jiangnan Liu
ZZZhongyong Zhao
Zhongyong Zhao
KPKai Pang
Kai Pang
DWDong Wang
Dong Wang
CTChao Tang
Chao Tang
CYChenguo Yao
Chenguo Yao
The accurate and fast diagnosis of transformer winding deformation faults is of significance to power suppliers and utilities. An improved winding mechanical deformation fault classification method is proposed. In this study, the transformer frequency response data is used to draw polar plots, and then its texture features are extracted for fault classification. The classification model constructed by multiple support vector machines is successfully obtained and shows good classification effect. Besides, this paper uses an improved genetic algorithm based on the Emperor-Selective mating scheme and catastrophic operation, to optimize the parameters of support vector machine. The feasibility and accuracy of the proposed method are verified with experimental data obtained from a model transformer, and the proposed method is demonstrated to exhibit better performance compared with the traditional method.

15 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
ZZZhongyong Zhao
Zhongyong Zhao
JLJiangnan Liu
Jiangnan Liu
WWWei Wang
Wei Wang
CYChenguo Yao
Chenguo Yao
Winding short-circuit (SC) faults are a prevalent issue in synchronous machines, and the accurate and timely identification of these faults is critical for maintaining power system stability. Current methods for inspecting synchronous machine windings often rely on periodic inspections based on human expertise. Numerous studies have explored the application of deep learning (DL) models for detecting synchronous machine winding SC faults. However, these models often exhibit excessive complexity and overlook physical overhead, leading to inefficient utilization of computational power and data resources. To address these limitations, this study proposes a dual-channel deep learning (DL) model integrated with the active learning (AL) query strategy. In this study, winding SC faults are manually simulated on a 5 kVA synchronous machine, and corresponding frequency response analysis (FRA) data are recorded. Subsequently, the proposed method is validated on the test set and benchmarked against previous studies. Experimental results demonstrate that the proposed method significantly reduces the data annotation effort and accelerates model training to the order of seconds (under 5 seconds) while maintaining satisfactory accuracy (≥ 95%). Comparative experimental results further indicate that the proposed model, requiring only 1/20th of the labeled training samples used in previous studies, achieves a substantial reduction of approximately 99.8% in both model parameters and training time.

29 April 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
ZCZhe Chen
Zhe Chen
YDYuxuan Ding
Yuxuan Ding
YDYa Ping Du
Ya Ping Du
BLBinghao Li
Binghao Li
ZZZhongyong Zhao
Zhongyong Zhao
Accurate diagnosis of transformer winding deformation faults is critical for ensuring the reliability and stability of power systems. However, the scarcity of real-world faulty frequency response analysis (FRA) data severely constrains the development of intelligent data-driven diagnostic models. To overcome this limitation, this study proposes a metric learning framework that integrates FRA with triplet loss and virtual adversarial training (VAT). The method first reformulates the original dataset of N FRA samples into N2 training pairs through the random pairing mechanism, thereby substantially expanding the effective training set. Triplet loss is then applied to further enrich sample diversity (≈ N3) and enhance model feature extraction. To address the inherent label imbalance arising from random pairing, VAT is incorporated. This regularization technique generates synthetic intra-class pairs and enforces local smoothness in the embedding space. Experimental validation on a specially designed 10 kV transformer demonstrates that the proposed approach achieves superior diagnostic accuracy. When applied to two practical transformers with confirmed winding deformations, the trained model accurately identifies fault types. Importantly, the method offers a potential solution for detecting previously unknown winding faults.

20 November 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
JLJiangnan Liu
Jiangnan Liu
YDYuxuan Ding
Yuxuan Ding
YDYa Ping Du
Ya Ping Du
BLBinghao Li
Binghao Li
ZZZhongyong Zhao
Zhongyong Zhao
Frequency response analysis (FRA) is a well-established technique to detect transformer winding deformation faults. Its diagnostic application is based on the principle that a transformer winding can be represented by an equivalent circuit consisting of resistors, inductors, and capacitors. However, rapidly obtaining an accurate and physically meaningful broadband equivalent circuit model for windings remains challenging, limiting both the understanding of fault mechanisms and the generation of data for data-driven fault diagnosis methods. To address these difficulties, this study proposes a two-step broadband equivalent circuit modeling method for the transformer winding based on FRA and Bayesian optimization (BO), considering long-distance mutual inductances and capacitances. The proposed method is validated in a specially designed 10 kV power transformer. Subsequently, two kinds of winding deformation faults, including inter-disk short circuits (IDSCs) and disk space variations (DSVs), are simulated on the basis of the built model and compared with the experimental FRA data. The validation results confirm the accuracy and effectiveness of the proposed method in the construction of the equivalent winding circuit.