Arnaud Devred

Arnaud Devred

Auto-generated profile, based on publicly available information

Arnaud Devred

CERN, Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2005 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
ADA. Devred
A. Devred
Alan GourlayAlan Gourlay
Alan Gourlay
AYA. Yamamoto
A. Yamamoto
Superconducting magnet technology is continually evolving in order to meet the demanding needs of new accelerators and to provide necessary upgrades for existing machines. A variety of designs are now under development, including high fields and gradients, rapid cycling and novel coil configurations. This paper presents a summary of R&D programs in the EU, Japan and the USA. A performance comparison between NbTi and Nb/sub 3/Sn along with fabrication and cost issues are also discussed.

12 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
AHAriel Haziot
Ariel Haziot
GKGlyn Kirby
Glyn Kirby
ADAlessandro Dallocchio
Alessandro Dallocchio
ADArnaud Devred
Arnaud Devred
AFArnaud Foussat
Arnaud Foussat
JGJorge Guardia-Valenzuela
Jorge Guardia-Valenzuela
Due to its flexibility in generating advanced field harmonic corrections and potential for low cost compared to traditional designs, the Canted Cosine Theta (CCT) configuration is particularly interesting for compact particle accelerators and gantries for medical applications. This article presents the design of a curved demonstrator named Fusillo, a Canted Cosine Theta Nb-Ti dipole magnet that is being developed at CERN, featuring a large aperture of 236 mm, a small bending radius of 1 m, a bending angle of 90 $^{\circ }$ , and multi-harmonic field correction, with a 3.61 T conductor peak field. We detail the magnetic coil design, incorporating high-order magnetic field correction of the errors produced by the heavily curved coil, peak field reduction at the coil ends, the development of a new rope type cable, and the mechanical design and the development of the former that supports the coil and provides the curved shape. We also present the first results of a subscale model used to qualify the coil's former manufacturing process, the rope cable, the coil winding optimization, and the coil impregnation system.

11 December 2013 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
CSC. Sborchia
C. Sborchia
AOA. Bonito Oliva
A. Bonito Oliva
TBT. Boutboul
T. Boutboul
KCKaren Kar Loen Chan
Karen Kar Loen Chan
ADA. Devred
A. Devred
YWY. Wu
Y. Wu
Construction of the ITER magnet systems has been started at the end of 2007 following the signature of the first procurement arrangements (PA) for the toroidal field (TF) conductors. Six ITER members are involved in the share of the ITER magnet components and, to date, eighteen PA between the ITER Organization and six domestic agencies have been signed. Substantial progress towards full-scale construction has been achieved with the placement of the first large manufacturing contracts, the production of several tens of tons of advanced Nb3Sn and NbTi strand, and the set-up of large cabling and jacketing facilities. The detailed design of the coils and support structures has also been finalized. The qualification of the fabrication processes for the TF coils and poloidal field (PF) coils has been initiated. The detailed design of the central solenoid (CS) coils is being developed. The design of the correction coils (CCs) with their support structures has been finalized, as well as for the TF gravity supports and clamps of the PF coils. The manufacture of prototypes of the feeder lines and current leads has been started, while ITER is in charge of the procurement of the required magnet instrumentation. This paper provides a progress report on the ITER magnet construction as per December 2010.

23 April 2012 in Superconductor Science and Technology
Verified
Journal Article
Closed access
IPIan Pong
Ian Pong
AVAlexander Vostner
Alexander Vostner
BBBernardo Bordini
Bernardo Bordini
MJMatthew Jewell
Matthew Jewell
FLFeng Long
Feng Long
NMNeil Mitchell
Neil Mitchell

16 January 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SBSusana Izquierdo Bermudez
Susana Izquierdo Bermudez
GAGiorgio Ambrosio
Giorgio Ambrosio
GAGiorgio Apollinari
Giorgio Apollinari
ABAmalia Ballarino
Amalia Ballarino
CBChristian Barth
Christian Barth
GWGerard Willering
Gerard Willering
The cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

31 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GAGiorgio Ambrosio
Giorgio Ambrosio
KAKathleen Amm
Kathleen Amm
MAMichael Anerella
Michael Anerella
GAGiorgio Apollinari
Giorgio Apollinari
GIGonzalo Arnau Izquierdo
Gonzalo Arnau Izquierdo
MYMiao Yu
Miao Yu
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low-beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some of the criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this article, we present a summary of: 1) the fabrication and test data for all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.