Giuseppina Lopardo

Giuseppina Lopardo

Auto-generated profile, based on publicly available information

Giuseppina Lopardo

Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, Italy

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2014 in Geoscientific Instrumentation, Methods and Data Systems
Verified
Journal Article
Open access
PDF file
KWK. Willett
K. Willett
CWC. Williams
C. Williams
IJI. T. Jolliffe
I. T. Jolliffe
RLR. Lund
R. Lund
LAL. V. Alexander
L. V. Alexander
PTP. W. Thorne
P. W. Thorne
The International Surface Temperature Initiative (ISTI) is striving towards substantively improving our ability to robustly understand historical land surface air temperature change at all scales. A key recently completed first step has been collating all available records into a comprehensive open access, traceable and version-controlled databank. The crucial next step is to maximise the value of the collated data through a robust international framework of benchmarking and assessment for product intercomparison and uncertainty estimation. We focus on uncertainties arising from the presence of inhomogeneities in monthly mean land surface temperature data and the varied methodological choices made by various groups in building homogeneous temperature products. The central facet of the benchmarking process is the creation of global-scale synthetic analogues to the real-world database where both the "true" series and inhomogeneities are known (a luxury the real-world data do not afford us). Hence, algorithmic strengths and weaknesses can be meaningfully quantified and conditional inferences made about the real-world climate system. Here we discuss the necessary framework for developing an international homogenisation benchmarking system on the global scale for monthly mean temperatures. The value of this framework is critically dependent upon the number of groups taking part and so we strongly advocate involvement in the benchmarking exercise from as many data analyst groups as possible to make the best use of this substantial effort.

26 June 2013 in International Journal of Climatology
Verified
Journal Article
Open access
PDF file
GLG. Lopardo
G. Lopardo
FBF. Bertiglia
F. Bertiglia
SCS. Curci
S. Curci
GRG. Roggero
G. Roggero
AMA. Merlone
A. Merlone
Solar radiation screens play a key role in automatic weather stations (AWS) performances. In this work, screen ageing effects on temperature measurements are examined. Paired temperature observations, traceable to national standards and with a well‐defined uncertainty budget, were performed employing two naturally ventilated weather stations equipped with identical sensors and different only for their working time. Three different tests were carried out employing different aged AWSs: a 5‐year‐old AWS (AWS5) was compared with a new device (AWS0), a 1 year old (AWS1) was compared with both a 3 years old (AWS3) and a new one devices (AWS00). Due to solar and weather conditions exposure a degradation of the screen reflective coating is evident for the older AWSs (5 and 3 years old) and so a qualitative estimation of how different conditions of ageing affect the temperature drift was done. During the comparison 0 to 5 and 1 to 3‐year‐old screens, significant temperature differences were recorded at different times of the day. The differences, wider than the uncertainty amplitude, demonstrate a systematic effect. The temperature measured with the older screen is larger, and the maximum instantaneous difference was 1.63 °C (for 0–5 years comparison) in daytime hours. During night‐time the two AWS's measure the same temperature (within the uncertainty amplitude). This behaviour, increasing with increasing solar radiation intensity and decreasing with increasing wind speed, is attributed to a radiative heating effect. The screen ageing has compromised the shield effectiveness introducing a significant change in the temperature evaluation. The experimental results of a further comparison, between 0‐ and 1‐year‐old screens, confirm the same conclusion showing a negligible ageing effect, within the uncertainty amplitude.

2 February 2021 in Metrologia
Verified
Journal Article
Open access
PDF file
DRDaniele Madonna Ripa
Daniele Madonna Ripa
DIDario Imbraguglio
Dario Imbraguglio
CGChristof Gaiser
Christof Gaiser
PSPeter P M Steur
Peter P M Steur
DGDomenico Giraudi
Domenico Giraudi
RGRoberto Maria Maria Gavioso
Roberto Maria Maria Gavioso
We have measured the refractive index of helium using a quasi-spherical copper microwave resonator at five different temperatures in the interval between the triple point of hydrogen at 13.8 K and the triple point of xenon at 161.4 K for pressures up to 380 kPa. From these results and additional measurements of the refractive index of neon near 54.4 K, 83.8 K and 161.4 K we determine the differences (T − T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). We have estimated the isothermal compressibility of copper and the effective compressibility of our microwave resonator by different methods including resonant ultrasound spectroscopy (RUS) and microwave measurements with helium at 273.16 K. We compare the results of these compressibility estimates and discuss the associated uncertainty. From the refractive index measurements, we estimate the second density virial coefficient of helium and neon which are found in good agreement with the ab initio calculations of the same properties.

1 January 2023 in Metrologia
Verified
Journal Article
Closed access
THTobias Herman
Tobias Herman
MCMichal Chojnacky
Michal Chojnacky
KHKen Hill
Ken Hill
SRSteffen Rudtsch
Steffen Rudtsch
IYInseok Yang
Inseok Yang
JGJayne Gray
Jayne Gray
Main text: This is a report to the Consultative Committee for Thermometry (CCT) on the key comparison 9 of Standard Platinum Resistance Thermometer (SPRT) calibration on the International Temperature Scale of 1990 (ITS-90) [1] from 83.8058 K (the Ar triple point) to 692.677 K (the Zn freezing point). The comparison followed a collapsed star protocol, with each of the fourteen participating laboratories shipping two standard platinum resistance thermometers (SPRTs) as transfer standards to the pilot laboratory (National Institute of Standards and Technology, NIST) for a direct comparison of SPRT calibration at the National Metrology Institute (NMI) of origin to calibration at NIST. Measurements were taken at the participating laboratories before and after measurement at NIST to assess the effect of transportation on the transfer standards. The pooled results from all laboratories were combined to calculate a key comparison reference value (KCRV). This report includes the calculation of, and comparisons to, the KCRV as well as bilateral comparisons between labs. In addition, there is space devoted to analysis of the shifts in SPRT values following travel. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

26 February 2024 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SGStefania Gravina
Stefania Gravina
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
ACAntonio Castrillo
Antonio Castrillo
LGLivio Gianfrani
Livio Gianfrani
ASAlessia Sorgi
Alessia Sorgi
Gianluca GalzeranoGianluca Galzerano
Gianluca Galzerano
Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the (6s2)S01→(6s6p)P13 intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.

16 November 2015 in Meteorological Applications
Verified
Journal Article
Open access
PDF file
GLG. Lopardo
G. Lopardo
SBS. Bellagarda
S. Bellagarda
FBF. Bertiglia
F. Bertiglia
AMA. Merlone
A. Merlone
GRG. Roggero
G. Roggero
NJN. Jandric
N. Jandric
Environmental monitoring by automatic weather stations (AWSs) is growing as a result of the increasing number and reliability of surface observations. In order to ensure data traceability and obtain more comprehensive data on the performance of AWSs, a new transportable calibration facility was manufactured at the Italian Institute of Metrology (INRiM) in the framework of the project MeteoMet. The facility is equipped with temperature and pressure reference sensors directly traceable to the International System of Units (SI) to obtain meteorological data with well‐documented calibration uncertainty.In this calibration system, temperature and pressure can be controlled simultaneously and independently so that all combinations over the ranges are possible. The nominal ranges are: absolute pressure 50 to 110 kPa and temperature −25 to 50 °C. The availability of a large range of atmospheric variability and the possibility of studying the mutual influence effects on sensors response are important characteristics of the facility.This apparatus is also designed to permit a control in humidity, in order to complete the characterization of the whole AWS pressure–temperature–humidity modulus. As a matter of fact, the final version of the facility will be equipped with a humidity generator for hygrometer calibrations.Finally, the calibration system is designed to be transportable, therefore allowing the calibration of AWSs located at sites that are difficult to access such as Ny‐Ålesund (Svalbard) stations, where the facility was employed.The design and the technical characteristics are reported in this paper.