The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
26 November 2013 in Review of Scientific Instruments
Long pulse beam extraction with a current density of 120 A/m2 for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m2 (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.
1 April 2022 in Journal of Physics: Conference Series
Reverse calculation of negative ion trajectory based on the measured beam emittance has been performed for the first time in multi-stage accelerator in order to reconstruct negative ion profile near meniscus, which has been a long-term issue for negative ion sources. According to reverse calculation, negative ions are mainly extracted from the periphery of extraction area, and the particles extracted from the aperture edge is lost on acceleration grids. By taking into account the lost component with reconstructed negative ion profile, the negative ion trajectory became consistent with observed beam traces on the acceleration grids. This result can be applied directly to the design of ITER accelerator as well as the other Cs-seeded negative ion sources.
This overview summarizes the R&D activities aimed to secure for the ITER Neutral Beam Injectors a stable voltage holding, one of the most challenging issue for the NBI systems operation. The huge size of the accelerator and the highest voltage (1 MV) ever used in such systems make prominent some aspects that are, in other application, almost not influent or well under control, like the Area Effect, Total Voltage Effect, the highly complex electrostatic configuration and, last but not least, the cleaning degree of the electrodes surfaces. A clear explanation of the mechanism leading to the voltage breakdown in these conditions is far from being well established. But in the last years a great effort have been deployed by the NBI community to reliably achieve 1 MV voltage holding that is required for the NB injectors for ITER. Theoretical models and new tools have been derived to explain the mechanism of voltage conditioning and for the design of the complex electrodes geometries, that supersede the simple electric field optimization. The 1 MV across a single gap has not yet been achieved but, on the basis of the results so far obtained, it is now considered to be achievable.
A scaling technique has been developed in order to predict the voltage holding capability of the world-largest electrostatic accelerator for fusion application having a long gap vacuum insulation around 1 m with large surface area of more than 6 m 2 . One of critical issues for design of such large-size accelerator is the development of the prediction model based on the experimental results. For this purpose, the 1/5 scale mockup has been developed, which is composed of the 5-stage accelerator with the high voltage bushing in the vacuum vessel. Direct comparison of the sustainable voltages in the 1/5 scale and full-scale high voltage busing only shows that a voltage scaling in 1/5 scale size is 55%. It was found that the voltage scaling is consistent with the prediction based on the empirical scaling according to the surface area and gap length. As a result, the voltage holding capability of the 1/5 scale mockup is 400 kV in the experiment, which indicates an estimation of 720 kV in full-scale with a real configuration. This is the first experiment-based prediction of the voltage holding capability for the largest accelerator for ITER. The improvement of the voltage holding capability has been already planned by using multi-layer electrostatic shields. In such experiment, the developed scaling technique is useful to predict the voltage holding capability for large vacuum components which can not be easily tested.
1 January 2011 in The Proceedings of the Dynamics & Design Conference