Tao Chen

Tao Chen

Auto-generated profile, based on publicly available information

Tao Chen

Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2017 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
TCTao Chen
Tao Chen
XJXiankun Jin
Xiankun Jin
RGRandall L. Geiger
Randall L. Geiger
DCDegang Chen
Degang Chen
Linearity testing of analog-to-digital converters (ADCs) is very challenging and expensive due to the stringent linearity requirement on the stimulus and the extremely long test time. This paper introduces a novel method for ADC static linearity testing, allowing the stimulus linearity requirement to be significantly relaxed and the test time to be significantly reduced compared to the state-of-art histogram method. Two nonlinear but functionally related input signals are used as the ADC's excitation and a stimulus error removal technique is used to recover test accuracy. With a segmented non-parametric integral nonlinearity model, this method requires much fewer parameters to accurately represent the nonlinearity. The proposed algorithm has been extensively verified and correlated in simulations. This method not only enables low-cost production testing but can also be used for low-cost on-chip built-in self-test. This method is limited to ADCs with segmented architecture such as SAR ADCs, pipeline ADCs, and cyclic ADCs.

1 April 2015
Verified
Conference Paper
Closed access
TCTao Chen
Tao Chen
DCDegang Chen
Degang Chen
Linearity test of an analog-to-digital converter (ADC) can be very challenging because it requires a signal generator substantially more linear than the ADC under test. For high performance ADCs, the overall manufacturing cost could be dominated by the long test time and the high-precision test instruments. This paper introduces the ultrafast stimulus error removal and segmented model identification of linearity errors (USER-SMILE) method for high resolution ADC linearity test, allowing the stimulus signal's linearity requirement to be significantly relaxed and the test time to be reduced by orders of magnitude compared to the state-of-art histogram method. The USER-SMILE algorithm uses two nonlinear but functionally related input signals as ADC excitations and uses a stimulus error removal technique to recover test accuracy. The USER-SMILE algorithm also uses the ultrafast segmented model identification of linearity errors (uSMILE) approach to dramatically reduce test time while achieving test accuracy and coverage superior to the histogram method. The USER-SMILE algorithm is validated by extensive simulation with different types of ADCs, different resolution levels, and different types of input signals including nonlinear ramps, nonlinear sine waves and even random input signals. Statistical simulation results show that for a 16-bit SAR ADC, with two 1 hit/code nonlinear ramp signals, the INL test error is within +/- 0.4LSB.

16 November 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYuming Zhuang
Yuming Zhuang
BMBenjamin Magstadt
Benjamin Magstadt
TCTao Chen
Tao Chen
DCDegang Chen
Degang Chen
Data converters are among the most widely used components in modern integrated devices and systems. A major challenge is to characterize their performances accurately and cost effectively. The analog-to-digital converter (ADC) standard test requires the input sinusoidal signal to be 3-4 b better than that of the ADC under test. Such high-quality sine waves are extremely difficult to generate and challenging to implement cost effectively. This paper presents a novel method that is capable of generating a high-purity sine wave using a nonlinear digital-to-analog converter (DAC), whose purity is significantly better than the original DAC output. In addition, with the aid of the low-cost DAC-ADC co-testing method, both DAC and ADC linearity information are accurately obtained with only 1 hit per code. Therefore, it is possible to add DAC linearity information to the DAC input codes, which cancels the nonlinearity of the DAC at output to achieve high purity. The proposed method has been validated by extensive simulation and measurement results, which demonstrated its accuracy and robustness against different resolutions, structures, or performance of the ADCs/DACs. With its low cost and easy test setup, such high-purity sine wave can be widely used for various applications where precision testing is required. In addition, the ADC and DAC linearity information is accurately obtained at the same time without any precision instrumentation, which is suitable for accurate DAC-ADC co-testing.

11 August 2016
Verified
Conference Paper
Closed access
YDYan Duan
Yan Duan
TCTao Chen
Tao Chen
DCDegang Chen
Degang Chen
The ultrafast segmented model identification of linearity error (uSMILE) algorithm dramatically reduces ADC linearity test time while achieving superior test accuracy. This method avoids the gross inefficiencies in the conventional histogram test method to reduce the test data by a factor of over 100. However, in low noise environment where the quantization noise becomes dominant, uSMILE leads to large (up to +/-0.5 LSB) INL estimation error. In this case, proper extra noise needs to be added to the stimulus in order to whiten the quantization noise. In this paper, a pseudo random dithering method and a low-cost implementation of dithering generator in SAR ADC are proposed. The random pattern is generated from a simple shift register and XOR gate. The dithering is added through the dummy capacitor of SAR ADC during the ADC sampling phase. The proposed scheme is validated through extensive simulations. The maximum INL estimation error in a 12-bit ADC with 1 hit/code ramp test is within ± 0.1LSB.

13 July 2020 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
CPChulhyun Park
Chulhyun Park
TCTao Chen
Tao Chen
KNKyoohyun Noh
Kyoohyun Noh
DZDadian Zhou
Dadian Zhou
SPSuraj Prakash
Suraj Prakash
JSJose Silva-Martinez
Jose Silva-Martinez
This paper introduces a 12 bit 2.5 bit/cycle SAR-based pipeline ADC employing a self-bias gain boosting amplifier. The single-stage amplifier achieves a low-frequency gain of 37 dB, while consuming 1.3 mW of power consumption with 1.3 V of analog power supply. A 2.5 bit/cycle SAR ADC realizes as the sub-ADC in each stage, and reduces both power consumption and silicon area. A two-channel sampling architecture is employed to double the sampling rate and thereby maximize circuit efficiency. A digital calibration technique is used to reduce non-linearity and mismatches due to the RDAC, as well as gain error and offset of the open-loop residue amplifier. The prototype ADC was fabricated in TSMC 40-nm technology, and consumes 10.71 mW with 1.1 V / 1.3 V digital / analog power supplies. When operating at 125 MS/s, the ADC achieves an SFDR of 66.59 dB before calibration and 80.3 dB after calibration when measured at Nyquist frequency. The experimental results show a Walden FoM of 101 fJ/c.-s. before calibration and 47 fJ/c.-s. after calibration.

16 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TCTao Chen
Tao Chen
CPChulhyun Park
Chulhyun Park
SCShravan Kumar Chaganti
Shravan Kumar Chaganti
JSJose Silva-Martinez
Jose Silva-Martinez
RGRandall L. Geiger
Randall L. Geiger
DCDegang Chen
Degang Chen
A novel ultrafast and low-cost pipelined analog-to-digital converter (ADC) testing and calibration method is proposed. The ADC nonlinearities are modeled as segmented parameters with interstage gain errors. During the test phase, a pure sine wave is sent as input and the model parameters are estimated from the output data with the system identification method. Significantly, fewer samples are required when compared to traditional histogram testing. The modeled errors are then removed from the digital output codes during the calibration phase. Extensive simulations have been run to verify the correctness and robustness of the proposed method. With just 4000 samples, a 12-bit ADC can be accurately tested and calibrated to achieve less than 1 least significant bit (LSB) integral nonlinearity (INL). Measurement results show that the ADC effective number of bits (ENOB) is improved from 9.7to 10.84 bits and the spurious-free dynamic range (SFDR) is improved by 20 dB after calibration. The chip is fabricated in 40-nm technology and consumes 10.71 mW at a sampling rate of 125 MS/s.