kyeongwon jeong

Prof. Dr. kyeongwon jeong

school of integrated technology, Yonsei University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2023 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
kyeongwon jeongkyeongwon jeong
kyeongwon jeong
Sohmyung HaSohmyung Ha
Sohmyung Ha
MJMinkyu Je
Minkyu Je
This article presents a discrete-time $\Delta \Sigma $ modulator (DSM) with a wide linear input range and high input impedance for biomedical signal acquisition. The proposed integrated circuit (IC) is based on a 1st-order DSM with 2nd-order noise-shaping (NS)-successive approximation (SAR) for high resolution with high power efficiency, directly converting the small input signal to digital. The first-stage integrator in the DSM is designed to support not only for wide-input swing at low power consumption but also for high input impedance. The input impedance is further boosted by a proposed presampling-based charge-transfer-reduction technique, which does not require any additional amplifiers. It precharges the sampling capacitor with just the previous sampled signal, thus reducing the charge transfer and boosting the input impedance. Besides, we also propose a new truncation-error shaping method. By feeding the truncation error back to the local NS-SAR loop, the truncation error is effectively noise-shaped without using any additional loop, resulting in 4th-order NS. The prototype IC is fabricated in a 65-nm CMOS process. It achieves 94.5-dB signal-to-noise-and-distortion ratio (SNDR) for 1–500-Hz bandwidth with 600-mVPP input applied, resulting in FoMSNDR of 174.3 dB and FoMDR of 175.8 dB. It achieves over 83-dB common-mode rejection ratio (CMRR) and input impedance of 208 $\text{M}\Omega $ at dc and 31.5 $\text{M}\Omega $ at the target bandwidth. Moreover, its artifact tolerance is verified by in vitro and in vivo measurements.

26 May 2022 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
WAWoojin Ahn
Woojin Ahn
DKDoohee Kim
Doohee Kim
JPJonghyeok Park
Jonghyeok Park
JPJoeng Hoan Park
Joeng Hoan Park
TLTaeju Lee
Taeju Lee
MJMinkyu Je
Minkyu Je
This letter presents a neural stimulation IC for the 32-channel cochlear implant system. A zoom current DAC (I-DAC), whose full range is reconfigured to fit the interval between the comfort (C) and threshold (T) levels, is introduced for high-resolution stimulation strength control to provide high-fidelity sound perception with minimal hardware overhead. The IC also includes an in-situ neural recording function. The effectiveness of auditory nerve stimulation is validated by monitoring electrically evoked compound action potential (ECAP) in-vivo using a rat model. It is found that the action potential amplitude increases as the stimulation current level becomes larger.

26 July 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
kyeongwon jeongkyeongwon jeong
kyeongwon jeong
YJYoontae Jung
Yoontae Jung
GYGichan Yun
Gichan Yun
DYDonghyun Youn
Donghyun Youn
YJYehhyun Jo
Yehhyun Jo
MJMinkyu Je
Minkyu Je
This paper presents a PVT-robust error-feedback (EF) noise-shaping SAR (NS-SAR) ADC for direct neural-signal recording. For closed-loop bidirectional neural interfaces enabling the next generation neurological devices, a wide-dynamic-range neural recording circuit is required to accommodate stimulation artifacts. A recording structure using an NS-SAR ADC can be a good candidate because the high resolution and wide dynamic range can be obtained with a low oversampling ratio and power consumption. However, NS-SAR ADCs require an additional gain stage to obtain a well-shaped noise transfer function (NTF), and a dynamic amplifier is often used as the gain stage to minimize power overhead at the cost of vulnerability to PVT variations. To overcome this limitation, the proposed work reutilizes the capacitive-feedback amplifier, which is the analog front-end of the neural recording circuit, as a PVT-robust gain stage to achieve a reliable NS performance. In addition, a new chopper-based implementation of a passive high-pass IIR filter is proposed, achieving an improved NTF compared to prior EF NS-SAR ADCs. Fabricated in a 180-nm CMOS process, the proposed NS-SAR ADC consumes 4.3-μW power and achieves a signal-to-noise-and-distortion ratio (SNDR) of 71.7 dB and 82.7 dB for a bandwidth of 5 kHz and 300 Hz, resulting in a Schreier figure of merit (FOM) of 162.4 dB and 162.1 dB, respectively. Direct neural recording using the proposed NS-SAR ADC is demonstrated successfully in vivo , and also its tolerance against stimulation artifacts is validated in vitro .

25 May 2023 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
kyeongwon jeongkyeongwon jeong
kyeongwon jeong
GYGichan Yun
Gichan Yun
JCJae Suk Choi
Jae Suk Choi
ICInjun Choi
Injun Choi
JSJeehoon Son
Jeehoon Son
MJMinkyu Je
Minkyu Je
This article presents an ultrasound (US) transceiver IC including a highly power-efficient US receiver (RX) and a high-voltage (HV) US transmitter (TX) for US capsule endoscopy (USCE) systems for the first time. The proposed USCE system employs the developed IC, a single-element piezoelectric transducer (PZT), and a mechanically rotating reflector to obtain 360 $^{\circ}$ transmural scans while traveling through the gastrointestinal (GI) tract. Since the USCE system operates with a tiny battery, power efficiency is greatly important. To reduce power consumption by decreasing the required operating speed of the analog-to-digital converter (ADC), we propose a new RX structure employing synchronized analog envelope detection. It is unlike conventional US RX ICs that necessitate power-hungry high-speed ADCs to acquire the US signal residing at a high center frequency with wide bandwidth. Instead, the proposed work employs an analog envelope detector based on a quadrature demodulation method. As a result, it uses only a single circuit path rather than two (I and Q) paths by using a demodulation carrier whose phase is synchronized with the incoming US signal. A ping-pong noise-shaping (NS) SAR ADC is adopted to improve resolution while maintaining low power consumption. Besides, the TX IC, including an on-chip charge pump, is designed to generate HV pulses to drive the PZT. The prototype IC is fabricated in a 0.18 $\mu$ m bipolar-CMOS-DMOS (BCD) process. The RX consumes 2.3 mW, and the ADC achieves a 53.71 dB SNDR and a 66.45 dB SFDR. The TX generates 25 V pulses with 25 ns pulsewidth. US B-mode images of a water tank and a custom phantom are successfully obtained by using the prototype capsule endoscopy system employing the fabricated IC chip.

19 May 2022 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
YJYoontae Jung
Yoontae Jung
Soon-Jae KweonSoon-Jae Kweon
Soon-Jae Kweon
TLTaeju Lee
Taeju Lee
kyeongwon jeongkyeongwon jeong
kyeongwon jeong
Sohmyung HaSohmyung Ha
Sohmyung Ha
MJMinkyu Je
Minkyu Je
This brief reviews the principle and design of dynamic range (DR) enhancement techniques for artifact-tolerant biopotential-acquisition ICs. In order to record small input signals without being disturbed by large artifacts, which may arise from motion or stimulation, biopotential-acquisition ICs for wearable devices and bidirectional neural interfaces should have wide DR in addition to low noise and high power efficiency. This review discusses key features of DR enhancement techniques based on three topologies: (1) saturation-free instrumentation amplifier with analog-to-digital converter (ADC), (2) signal-to-noise-and-distortion ratio (SNDR) enhanced ADC, and (3) DR-enhanced ADC with moderate linearity, which are used in state-of-the-art artifact-tolerant biopotential-acquisition ICs.

23 February 2024 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
GYGichan Yun
Gichan Yun
kyeongwon jeongkyeongwon jeong
kyeongwon jeong
HCHaidam Choi
Haidam Choi
SNSeunghyun Nam
Seunghyun Nam
COChaerin Oh
Chaerin Oh
MJMinkyu Je
Minkyu Je
In this letter, we present an ultrasound (US) imaging system with a low-noise US receiver (RX) and an element-level US transmitter (TX) for a capacitive micromachined ultrasonic transducer (CMUT). The proposed US RX isolates the input parasitic capacitance (CP) from the front-end transimpedance stage by using a bandwidth-enhanced current conveyor. By reducing the effects of the CP, the noise and power efficiency are improved compared to the conventional current readout circuits. Also, a US TX having a class-D output stage is implemented to excite the CMUT with 30-V unipolar pulses. Fabricated in a 180-nm BCD process, the proposed US RX achieves input-referred noise of 2.0 pA/Hz at 7.5 MHz and a bandwidth of 18 MHz with 25-pF CMUT capacitance while consuming 3.62 mW.