Intelligent Transport Systems (ITS) require accurate information to be shared among vehicles and infrastructure nodes for applications including accident information or pre-crash warnings, to name a few. Due to its sensitive nature, ITS applications are vulnerable against data integrity attacks where nodes transmit false information that results in wrong decision making by the applications. A characteristic of such attacks is that the false transmitted information is significantly different than the actual information. In this paper, we propose an Outlier Detection, Prioritization and Verification (ODPV) protocol that efficiently isolates false data and improves traffic management decisions. ODPV uses the isolation forest algorithm to detect outliers, fuzzy logic to prioritize outliers and C-V2X communications to verify the outliers. Extensive simulation results verify the effectiveness of the proposed protocol to isolate the outliers.
The aim of this paper is to design, analyze and optimize the “Multi-Stack Slotless Axial Flux Switching Permanent Magnet Machine”. In the design process, mathematical models are implemented, and the Finite Element Method (FEM) is performed to analyze the machine performances. The paper aims to minimize the occurrence of cogging torque and torque ripple in the multi-stack slotless stator AFPM machine. As a consequence, it reduces the vibrations in the machine and increases its life span. Multi-stack slotless stator AFPM machine with a right-angled trapezoid-shaped PM is proposed and comparison is done with conventional shape AFPM machine. In order to examine the performance of multi-stack slotless stator AFPM machine Finite Element Analysis (FEA) is used. To further enhance the characteristics of the designed machine with the proposed right-angled PM shape, optimization is done by considering inner and outer pole pitch as the design variables. In optimization process, krigging method assigned with Latin Hyper-cube Sampling and a genetic algorithm (GA) is performed due to suitability with non-linear data. Then, finite element analysis by JMAG-Designer is performed to verify the results. It is determined that optimized model has achieved 65% reduction in torque ripples as compared with the conventional design. Hence, this work attempts to optimize the performance of the AFPM machine.
Voltage instability in a power system produces low-frequency oscillations (LFOs), causing adverse effects in power distribution. Intelligent control schemes can overcome the limitations of fixed-parameter structures in power system stabilizers (PSS). Flexible alternating current transmission system (FACTS) control along with some supplementary control have remarkable potential in damping the oscillations. This paper proposes an adaptive neurofuzzy based recurrent wavelet control (ANRWC) scheme to enhance the power system stability. The proposed scheme utilizes recurrent Gaussian as antecedent part’s membership function and recurrent wavelet function in consequent parts. Our scheme uses gradient descent, adadelta, adaptive moment estimation (ADAM) and proximal gradient descent algorithms for optimization in which parameters of the scheme are updated using a back-propagation algorithm. A multi-machine power system is used for testing the controller. We evaluate the proposed control scheme in comparison to conventional lead-lag control and an adaptive neurofuzzy takagi sugeno kang (ANFTSK) control scheme. For comparison, we calculate the performance indices (PIs) for different controllers. Both quantitative and qualitative evaluations assert the effectiveness of the proposed control as compared to other schemes.
Permanent magnet vernier machines (PMVMs) are becoming progressively attentive because of their high efficiency and high torque density and can thus be utilized for direct-drive applications such as wind power and electric vehicles etc. This paper presents performance improvement of multi-rotor axial flux vernier permanent magnet (MR-AFVPM) machine with a proposed two-stage parallelogram-shaped PM. The proposed shaped PM reduces the cogging torque and torque ripples due to its skew effect. Furthermore, it also presents a comparative analysis of the conventional and proposed shape PM. Then 3D finite element analysis (FEA) is used for comparative analysis. Genetic algorithm (GA) associated with kriging method based on LHS is introduced and is used to optimize the proposed shaped PM for further performance improvement in terms of cogging torque, back EMFs, torque ripples, VTHD, output torque, flux density distributions, power factor and output power of the analyzed machines which are validated by 3D-FEA.
Power system stability continues to be a major challenge as modern grids grow more complex, uncertain, and increasingly reliant on renewable energy sources. This paper presents two new Neuro-Fuzzy controllers for Static Synchronous Compensators (STATCOMs): the Direct Chebyshev Wavelet-Based Neuro-Fuzzy Controller (DNF-CW), which adapts parameters online using fixed-structure rules, and the Indirect Chebyshev Wavelet-Based Neuro-Fuzzy Controller (IDNF-CW), which uses an online identifier to measure plant sensitivity. Chebyshev wavelet-based neural networks are utilized in the consequent part of both controllers to enable accurate local modeling and improved damping performance. The proposed methods are evaluated using a Single Machine Infinite Bus (SMIB) system and the IEEE 9-bus multi-machine system under a variety of fault and loading conditions. Benchmark comparisons include a conventional Indirect Adaptive Neuro-Fuzzy Takagi–Sugeno–Kang (IDNF-TSK) based controller, a configuration without STATCOM (No STATCOM), and a configuration with STATCOM but without auxiliary control (No Control). In the SMIB scenario, the IDNF-CW achieves a 40% reduction in settling time compared to the IDNF-TSK. In the more demanding multi-machine setup, the IDNF-CW restores stability within 3 seconds after a sequence of faults, outperforming DNF-CW and IDNF-TSK. Additionally, reductions of over 53% in the Integral of Time-weighted Absolute Error (ITAE) and 36% in the Integral of Absolute Error (IAE) are observed. These tests under multiple fault conditions and 10% measurement noise confirm stable operation, with overshoot limited to 3.57%–4.7% and minimal impact on settling time. These findings highlight the effectiveness of combining Chebyshev wavelets, adaptive control, and indirect architectures for enhancing power system stability.