Vesna Stanković

Dr. Vesna Stanković

University of Belgrade Institute for chemistry, technology and matalurgy, Belgrade, Beograd, Serbia
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
VSVesna Stanković
Vesna Stanković
SĐSlađana Đurđić
Slađana Đurđić
Miloš OgnjanovićMiloš Ognjanović
Miloš Ognjanović
BABratislav Antić
Bratislav Antić
KKKurt Kalcher
Kurt Kalcher
DSDalibor M. Stanković
Dalibor M. Stanković

1 October 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
VSVesna Stanković
Vesna Stanković
SDSladjana Djurdjic
Sladjana Djurdjic
Miloš OgnjanovićMiloš Ognjanović
Miloš Ognjanović
BABratislav Antić
Bratislav Antić
KKKurt Kalcher
Kurt Kalcher
DSDalibor Stankovic
Dalibor Stankovic

29 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AMAleksandar Mijajlović
Aleksandar Mijajlović
Miloš OgnjanovićMiloš Ognjanović
Miloš Ognjanović
Dragan ManojlovićDragan Manojlović
Dragan Manojlović
FVFilip Vlahovc
Filip Vlahovc
SDSladjana Djurdjic
Sladjana Djurdjic
DSDalibor Stankovic
Dalibor Stankovic
There are ten million people in the world who have Parkinson’s disease. The most potent medicine for Parkinson’s disease is levodopa (L-DOPA). However, long-term consumption of L-DOPA leads to the appearance of side effects, as a result of which the control and monitoring of its concentrations are of great importance. In this work, we have designed a new electrochemical sensor for detecting L-DOPA using a carbon paste electrode (CPE) modified with Eu2O3@Cr2O3 composite nanoparticles. Rare earth elements, including Eu, are increasingly used to design new electrode nanocomposites with enhanced electrocatalytic properties. Europium has been considered a significant lanthanide element with greater redox reaction behavior. We conducted a hydrothermal synthesis of Eu2O3@Cr2O3 and, for the first time, the acquired nanoparticles were used to modify CPE. The proposed Eu2O3@Cr2O3/CPE electrode was investigated in terms of its electrocatalytic properties and then used to develop an analytical method for detecting and quantifying L-DOPA. The proposed sensor offers a wide linear range (1–100 µM), high sensitivity (1.38 µA µM−1 cm−2) and a low detection limit (0.72 µM). The practical application of the proposed sensor was investigated by analyzing commercially available pharmaceutical tablets of L-DOPA. The corresponding results indicate the excellent potential of the Eu2O3@Cr2O3/CPE sensor for application in real-time L-DOPA detection.

6 April 2018 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
VSVesna Stanković
Vesna Stanković
SDSladjana Djurdjic
Sladjana Djurdjic
Ľubomír ŠvorcĽubomír Švorc
Ľubomír Švorc
TVTanja Ćirković Veličković
Tanja Ćirković Veličković
JMJelena Mutić
Jelena Mutić
DSDalibor Stankovic
Dalibor Stankovic

1 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SKSara Knežević
Sara Knežević
Miloš OgnjanovićMiloš Ognjanović
Miloš Ognjanović
VSVesna Stanković
Vesna Stanković
MZMilena Zlatanova
Milena Zlatanova
ANAndrijana Nesic
Andrijana Nesic
DSDalibor Stankovic
Dalibor Stankovic
This paper aims to develop an amperometric, non-enzymatic sensor for detecting and quantifying UA as an alert signal induced by allergens with protease activity in human cell lines (HEK293 and HeLa). Uric acid (UA) has been classified as a damage-associated molecular pattern (DAMP) molecule that serves a physiological purpose inside the cell, while outside the cell it can be an indicator of cell damage. Cell damage or stress can be caused by different health problems or by environmental irritants, such as allergens. We can act and prevent the events that generate stress by determining the extent to which cells are under stress. Amperometric calibration measurements were performed with a carbon paste electrode modified with La(OH)3@MWCNT, at the potential of 0.3 V. The calibration curve was constructed in a linear operating range from 0.67 μM to 121 μM UA. The proposed sensor displayed good reproducibility with an RSD of 3.65% calculated for five subsequent measurements, and a low detection limit of 64.28 nM, determined using the 3 S/m method. Interference studies and the real sample analysis of allergen-treated cell lines proved that the proposed sensing platform possesses excellent sensitivity, reproducibility, and stability. Therefore, it can potentially be used to evaluate stress factors in medical research and clinical practice.

22 March 2024 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
TMTijana Mutić
Tijana Mutić
Miloš OgnjanovićMiloš Ognjanović
Miloš Ognjanović
DIDjurdja Ivkovic
Djurdja Ivkovic
VNVladimir Nikolić
Vladimir Nikolić
VSVesna Stanković
Vesna Stanković
DSDalibor Stankovic
Dalibor Stankovic