Cristina Mazzotta

Cristina Mazzotta

Auto-generated profile, based on publicly available information

Cristina Mazzotta

ENEA, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Frascati Research Center, via Enrico Fermi 45, 00044 Frascati, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2017 in Nuclear Fusion
Verified
Journal Article
Open access
ABA. Bruschi
A. Bruschi
EAEdoardo ALESSI
Edoardo ALESSI
WBW. Bin
W. Bin
ODO. D’aRcangelo
O. D’aRcangelo
BBB. Baiocchi
B. Baiocchi
UTU. Tartari
U. Tartari

20 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
DPDavide Paloschi
Davide Paloschi
APAndrea Polimadei
Andrea Polimadei
Sanzhar KorganbayevSanzhar Korganbayev
Sanzhar Korganbayev
VOValerio Orsetti
Valerio Orsetti
CMCristina Mazzotta
Cristina Mazzotta
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Embedding optical fibers with fiber Bragg grating (FBG) sensors in 3D-printed samples can effectively facilitate the systematic use of smart materials in many fields such as civil, bio-medical and soft robotics applications. The aim of the study is to analyze different combinations of filament materials and FBG coatings, and to assess their metrological characteristics. Eighteen samples are fabricated and tested under different mechanical and thermal conditions. The repeated tests allow to perform an evaluation of the measurement repeatability for each sample, along with an analysis of the samples sensitivity. The filaments employed are acrylonitrile butadiene styrene (ABS), polylactic acid (PLA), and thermoplastic polyurethane (TPU). The fiber coatings are acrylate, Ormocer® and polyimide. The fiber coating has no significative influence on the performance of the sensors. The tests for temperature sensitivity highlight a good performance of ABS (116 pm/°C) and TPU samples (32 pm/°C) up to 60 °C, whereas the fabricated PLA samples (139 pm/°C for polyimide, 55 pm/°C for acrylate, 14 pm/°C for Ormocer®) cannot be used above 40 °C. The tests for strain sensitivity in axial elongation show an average sensitivity of 3.049 nm/mm for ABS, 1.991 nm/mm for PLA, 3.726 nm/mm for TPU. The bending tests show that all specimens materials have different sensitivity to elongation (2.994 nm/mm for ABS, 0.668 nm/mm for PLA, 0.149 nm/mm for TPU). Only for acrylate in PLA samples an effective difference for bending sensitivity resulted (1.241 nm/mm for the acrylate coating vs 2.366 nm/mm for the other coatings).

22 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GCGabriele Colombo
Gabriele Colombo
SASayyed Ashkan Adibi
Sayyed Ashkan Adibi
MBMarco Breschi
Marco Breschi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
ACAntonio Castaldo
Antonio Castaldo
Gianluca De MarziGianluca De Marzi
Gianluca De Marzi
In this article, we report the results from two test campaigns conducted to evaluate the feasibility of implementing a commercially available optical fiber-based distributed sensing technology for Quench Detection (QD) purposes. We successfully characterized the temperature response and sensitivity achievable by this technique when using a bare single mode fiber within a cryogen free cooling system operating in the temperature range from 4 K to 300 K. A fiber was also incorporated into a sample featuring an High-Temperature Superconductor (HTS) stack mounted onto an extruded Aluminum slotted-core cable. Quench-like events were triggered by locally lowering the critical current using the magnetic field produced by a set of permanent magnets placed near the center of the stack. The experiments were carried out at 77 K by cooling the sample through the central channel of the Aluminum core with a forced flow of liquid nitrogen. The test results indicate the viability of this technology as a suitable alternative for QD in long-length HTS cables and motivate further work to develop distributed sensing systems able to work in the conditions foreseen for HTS fusion coils.

1 March 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DFD. Fiorucci
D. Fiorucci
LGL. Giudicotti
L. Giudicotti
PIP. Innocente
P. Innocente
DTD. Terranova
D. Terranova
CMC. Mazzotta
C. Mazzotta
OTO. Tudisco
O. Tudisco
In magnetically confined fusion experiments, laser interferometer/polarimeter systems allow one to determine plasma density, give valuable information on the internal magnetic fields, and contribute to the evaluation of the plasma magnetic equilibrium and to the real-time estimation of the q profile to allow feedback configuration control. This work presents an analysis of the interferometric and polarimetric signals of a multi-chord far-infrared interferometer/polarimeter for the divertor tokamak test facility, the new tokamak device currently under construction in Italy. The polarimetric signals are calculated both with approximate formulas and by solving the equation describing the evolution of the laser beam polarization inside the plasma using the Mueller formalism. The latter method correctly accounts for crosstalk between Faraday rotation and the Cotton–Mouton effect. The impact of the plasma birefringence on the interferometric phase shift is also studied, and it is found that a perturbation of the interferometric phase shift is present also in the case of an initial fixed linear polarization of the probe laser beam.

12 December 2025 in Journal of Building Engineering
Verified
Journal Article
Open access
Stefano De SantisStefano De Santis
Stefano De Santis
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
SFSara Fares
Sara Fares
CMCristina Mazzotta
Cristina Mazzotta
GMGiovanni Moretti
Giovanni Moretti

4 January 2022 in Nuclear Fusion
Verified
Journal Article
Closed access
CMC. Mazzotta
C. Mazzotta
GPG. Pucella
G. Pucella
EGE. Giovannozzi
E. Giovannozzi
MMM. Marinucci
M. Marinucci
TTthe FTU Team
the FTU Team
In order to extend observations on the increase of electron density peaking in neon doped plasmas, already reported in FTU Mazzotta et al (2015 Nucl. Fusion 55 073027), some sessions have been performed by injecting helium gas on the L-mode plasmas during the last two experimental campaigns. This favorable scenario, which can fall within so called ‘highly radiative’ or ‘plasma detachment’ themes, is investigated in this paper. The description of the impact of the helium injection on plasma behavior, by varying plasma parameters and shape, is exposed, especially with respect to the density peaking and edge conditioning. It has been recorded that, not only the total amount of puffed helium, but also the injection rate intervenes in triggering a particle inflow. Finally, by using VUV spectroscopy measurements, a model to estimate concentrations of impurities is outlined here for the first time, in this way the helium amount is deduced.