This paper presents the characterization of an algorithm aimed at performing accurate fiber optic-based shape sensing. The measurement of the shape relies on the evaluation of the strains applied to an optic fiber in order to identify relevant spatial parameters, such as the curvature radii and bending direction, which define its shape. The measurement system is based on a 7-core multicore fiber, containing up to 9 triplets of fiber Bragg grating sensors (FBGs) organized around a central core used as reference. The proposed study aims at comparing the widely used Frenet-Serret equations with an algorithm based on the homogeneous transformation matrices that are normally used in robotics to express the position of a point in different frames, i.e. from local to global coordinates. The numerical results of the performed experiments (with different multicore fibers and setups) extensively prove the superiority of the alternative method over the Frenet-Serret equations in terms of finding a trade-off between accuracy and execution time.
20 September 2021 in IEEE Transactions on Instrumentation and Measurement
In this article, we propose a temperature-based proportional–integral–derivative (PID) controlling algorithm using highly dense fiber Bragg grating (FBG) arrays for laser ablation (LA) of ex vivo pancreatic tissues. Custom-made highly dense FBG arrays with a spatial resolution of 1.2 mm were fabricated with the femtosecond point-by-point writing technology and optimized for LA applications. In order to obtain proper PID gain values, finite element method-based iterative simulation of different PID gains was performed. Then, the proposed algorithm, with numerically derived PID gains, was experimentally validated. In the experiments, the point temperature was controlled at different distances from the laser fiber tip (6.0, 7.2, 8.4, and 10.8 mm). The obtained results report robust controlling and correlation between controlled distance and the resulting area of ablation. The results of the work encourage further investigation of FBG array application for LA control.
Inappropriate posture and the presence of spinal disorders require specific monitoring systems. In clinical settings, posture evaluation is commonly performed with visual observation, electrogoniometers or motion capture systems (MoCaps). Developing a measurement system that can be easily used also in non-structured environments would be highly beneficial for accurate posture monitoring. This work proposes a system based on three magneto-inertial measurement units (MIMU), placed on the backs of seventeen volunteers on the T3, T12 and S1 vertebrae. The reference system used for validation is a stereophotogrammetric motion capture system. The volunteers performed forward bending and sit-to-stand tests. The measured variables for identifying the posture were the kyphosis and the lordosis angles, as well as the range of movement (ROM) of the body segments. The comparison between MIMU and MoCap provided a maximum RMSE of 5.6° for the kyphosis and the lordosis angles. The average lumbo-pelvic contribution during forward bending (41.8 ± 8.6%) and the average lumbar ROM during sit-to-stand (31.8 ± 9.8° for sitting down, 29.6 ± 7.6° for standing up) obtained with the MIMU system agree with the literature. In conclusion, the MIMU system, which is wearable, inexpensive and easy to set up in non-structured environments, has been demonstrated to be effective in posture evaluation.
20 April 2023 in IEEE Transactions on Instrumentation and Measurement
Embedding optical fibers with fiber Bragg grating (FBG) sensors in 3D-printed samples can effectively facilitate the systematic use of smart materials in many fields such as civil, bio-medical and soft robotics applications. The aim of the study is to analyze different combinations of filament materials and FBG coatings, and to assess their metrological characteristics. Eighteen samples are fabricated and tested under different mechanical and thermal conditions. The repeated tests allow to perform an evaluation of the measurement repeatability for each sample, along with an analysis of the samples sensitivity. The filaments employed are acrylonitrile butadiene styrene (ABS), polylactic acid (PLA), and thermoplastic polyurethane (TPU). The fiber coatings are acrylate, Ormocer® and polyimide. The fiber coating has no significative influence on the performance of the sensors. The tests for temperature sensitivity highlight a good performance of ABS (116 pm/°C) and TPU samples (32 pm/°C) up to 60 °C, whereas the fabricated PLA samples (139 pm/°C for polyimide, 55 pm/°C for acrylate, 14 pm/°C for Ormocer®) cannot be used above 40 °C. The tests for strain sensitivity in axial elongation show an average sensitivity of 3.049 nm/mm for ABS, 1.991 nm/mm for PLA, 3.726 nm/mm for TPU. The bending tests show that all specimens materials have different sensitivity to elongation (2.994 nm/mm for ABS, 0.668 nm/mm for PLA, 0.149 nm/mm for TPU). Only for acrylate in PLA samples an effective difference for bending sensitivity resulted (1.241 nm/mm for the acrylate coating vs 2.366 nm/mm for the other coatings).
Accurate monitoring of classical dance movements, such as the demi plié and grand plié, is crucial for understanding postural dynamics and preventing injuries. In this work, the execution of the above-mentioned ballet exercises performed by one professional ballet dancer and nine amateurs is analyzed. The monitoring system consists in a 3D-printed wearable insole based on an optical fibre with eight fiber Bragg grating (FBG) sensors, employed to detect pressure changes and displacements of the center of pressure. In addition, standardized dimensionless indices (asimmetry index and time in boundary) are introduced and used for the evaluation of both asymmetries and a quantitative understanding of postural stability and muscle control during performance. The results prove that the FBG insole can detect pressure variations with high sensitivity (0.5-0.8 pm/kPa), showing significant differences between demi plié and grand plié in terms of maximum pressure (28.1 kPa × m2/kg for demi plié and 46.3 kPa × m2/kg for grand plié), and center of pressure stability. The FBG-based insole tailored for ballet dance activity and allowed comparison of the performance of the amateurs with the one of the professional dancer, and to identify potential errors during the execution of the exercises (e.g., heel lifting). The implemented methods and the obtained results allow to evaluate improvement solutions for training, readjust preparation and, in the future, identify possible injury sources.