The operation of single-phase Modular Multilevel Converter (MMC) is analyzed in the paper. A mathematical model of the converter is developed and described, based on which the structure and selection of parameters for Classical Control and Optimal Switching State Model Predictive Control (OSS-MPC) are defined. Additionally, the procedure for the determination of circuit parameters, such as submodule capacitance and arm inductance, is described and carried out. The listed control methods are designed and evaluated in Virtual Hardware-in-the-Loop together with single-phase MMC power circuit, regarding three control objectives: AC current control, voltage balancing control and circulating current control. Control methods are evaluated for both steady-state and transient performance and compared based on nine criteria: AC current reference tracking, THD of AC current and voltage, submodule capacitor voltage balancing, total submodule voltage control, circulating current magnitude and THD, number of control parameters and computational complexity. This is the first time that a fair comparison between Classical Control and MPC is considered in literature, resulting in superior performance of both control methods regarding four different criteria and the same performance regarding AC current reference tracking.
23 March 2025 in International Journal of Electrical Power & Energy Systems
Distribution grids are facing a great transformation in recent years with the advent of smart grid technologies. Particularly, more and more controllable devices, based on power electronics, are being deployed in this part of the power system. These interfacing devices are in charge of the active power management of many resources ranging from renewable energy sources to energy storage systems. For this reason, it has to be considered that power electronics may provide valuable ancillary services for improving the operation of distribution networks. With this regard, it is important to stress that low-voltage distribution systems and microgrids are by nature unbalanced due to single-phase loads. Consequently, the flexibility requirements and control capacities of converters interfacing distributed resources have to be greater with respect to those of balanced systems. This work proposes independent power control for each phase of a three-phase, four-wire virtual synchronous generator specially suited for these unbalanced environments. The technical feasibility of the control approach has been successfully validated through several Control Hardware-in-the-Loop tests analyzing both steady-state and transient responses as well as the performance on a microgrid scenario. In this last scenario, the performance of the proposal has been also compared to a virtual synchronous generator based on symmetric components decomposition.
Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a $\pm$525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).
U ovom radu se analizira sistem za prenos energije primenom rezonantnog pretvarača sa galvanskom izolacijom. Prikazani su principi funkcionisanja rezonantnih pretvarača i izvedeni su analitički izrazi za analizu njihovih performansi u ustaljenom stanju. Demonstriran je i postupak odredivanja parametara konkretne topologije rezonantnog pretvarača za prenos definisane vrednosti snage pri zadatim vrednostima ulaznog i izlaznog napona. Provera proračunatih parametara izvršena je pomoću simulacija u softverskom alatu za računarsku analizu električnih kola.
A Modular Multilevel Converter (MMC) is an innovative topology that has the potential to become widely used in all segments of industry, production, and power transmission, particularly at high and medium voltage levels. The transmission of electricity generated in offshore wind farms and HVDC systems are just some of the applications of this type of converter. MMC has been relatively well studied in terms of design and control, but very little research has been dedicated to the calculation or measurement of losses and efficiency. This paper focuses on conducting such a study, which can enhance the understanding of MMC advantages and provide further motivation for its application. In the paper, a converter model was formed using real switching components, enabling a detailed loss calculation. In addition to the efficiency, which is one of the key criteria for comparison with conventional topologies, the power loss value is also important from the perspective of designing cooling systems and, consequently, the complexity, total mass, and dimensions of the converter. Based on all the above, the aim was to propose an analytical model for loss calculation based on switching component information provided by the manufacturer. The results of the analytical calculation were compared with values previously obtained through loss modeling in the PLECS software package, confirming the accuracy of the presented analytical model. The contribution of the paper lies in the formation of a model that allows the calculation of MMC losses based on data available in the manufacturer’s catalog, which can be applied, without loss of generality, even in the case of a large number of submodules.