Osteoarthritis-oriented synovial fluid (OASF), i.e., that typical of a patient with osteoarthritis, has different physical and biological characteristics than bovine serum (BS), a lubricant widely ...
Experimental and numerical modeling of a heat pipe included with a phase change heat transfer was developed to assess the effects of three parameters of nanofluid, heat pipe inclination angles, and input heating power. Distilled water (DW) and 1-pyrene carboxylic-acid (PCA)-functionalized graphene nanofluid (with concentrations of 0.06 wt%) were used as working fluids in the heat pipe. A computational fluid dynamic (CFD) model was developed for evaluation of the heat transfer and two-phase flow through the steady-state process of the heat pipe. It was found that inclination significantly affects the heat transfer of the heat pipe. Maximum increment of thermal performance in the heat pipe reached 49.4% by using 0.06 wt% of PCA-functionalized graphene as working fluids. The result associated with this comparison indicates that the highest deviation is less than 6%, consequently confirming that the CFD model was successful in reproducing the heat and mass transfer processes in the DW and nanofluids charged heat pipe. The results of CFD simulation have good agreement between predicted temperature profiles and experimental data.
31 January 2011 in Materials and Manufacturing Processes
The flow of melted plastic in microparts is an interesting area to discover. Many studies have being conducted to understand the phenomena of polymer flow in microplastic parts. One type of study is the visualization of melted polymer flow. This work focuses on the observation of the micro-flow of melted Polypropylene (PP) using transparent polymethyl methacrylate (PMMA) mold. A PMMA mold with 0.5, 0.8, and 1.0 mm diameter channels were fabricated and injected with melted PP using a custom made vertical plastic injection molding machine. The flow of the melted PP can be clearly seen through the PMMA transparent mold. The result of the experimental are compared with a result from finite element analysis (FEA) software, MoldFlow Part Advisor. The result shows a good agreement for 1.0 and 0.8 mm channels, but not for the 0.5 mm. It can be concluded that, the analysis software is not capable of predicting the flow for 0.5 mm channel and less.
2 April 2014 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Metallic powder and binder mixing mechanism plays a vital role in the quality of molded parts in metal injection molding. The present study is intended for experimental and theoretical investigation of powder–binder mixing mechanism to investigate the functional correlation among mixing parameters and performance characteristics for different composition of feedstocks. Powder loading and shear rate are considered as input parameter. Fuzzy expert system is adopted to test the validity of the experimental results by analyzing different numerical error criteria using the viscosity as output with respect to input parameters. The mean relative error and correlation coefficient for type A and type B were found to be 6.09% and 8.51% (<10%) and 0.990 and 0.998, respectively. Hence the result indicates a reliable acceptability of the proposed amount of powder loading for feedstock preparation.
In the market, there are many types and shapes of syringes. One of the groupings of syringe types is based on barrel volume. The shape of the product design affects performance and user perception. The aim of this study is to investigate the effect of barrel volume on its performance and user perception. We performed analysis following international organization for standardization 7886 procedures on syringe with 1 mL, 3 mL, 5 mL, and 10 mL volume. In addition, a user perception test was conducted on 29 respondents using a questionnaire with the Likert chart method. This study indicates that the bigger the syringe volume, the larger the dead space and the force to operate the piston are. A larger syringe volume also raises the volume that changes due to the plunger position increase. Meanwhile, the barrel volume does not affect water and water leakage, as we did not observe any leak during the syringe tests in our experiment. In addition, the user perception test shows that the barrel’s length influences the ease of device control during the injection. The volume of the barrel negatively correlated with its effect to the environment. The safety features of all syringes are similar except for the 3 mL syringe, which has a value of 0.1 points difference to other syringes.