Irma Villar

Irma Villar

Auto-generated profile, based on publicly available information

Irma Villar

Department of Energy Storage and Power Electronics, Ikerlan Technology Research Centre, Basque Research and Technology Alliance (BRTA), Arrasate-Mondragn, Spain

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ATAitor Tovar-Barranco
Aitor Tovar-Barranco
ALAmaia Lopez-De-Heredia
Amaia Lopez-De-Heredia
IVIrma Villar
Irma Villar
FBFernando Briz
Fernando Briz
Modeling of convection heat-transfer at the end-windings for thermal networks using lumped-parameters has been widely discussed in the literature. Unfortunately, the resulting coefficients are highly influenced by the end-winding shape, the area in the vicinity of the end-windings, the cooling method of this region (if any), as well by the size and power of the machine. This makes it extremely difficult for the designer to choose a suitable coefficient for the thermal analysis during the design stage of an electric motor. A methodology to obtain the end-windings convection heat-transfer coefficients for fractional-slot concentrated winding permanent-magnet synchronous motors is proposed in this article. Machine designs with both internal and external rotors will be considered. The experimental tests required for the model characterization are described in detail. In this article, general expressions of the convection heat-transfer coefficients between the end-windings and the housing end-caps are proposed for both internal and external rotor designs. Differences observed with the results reported in the literature are also discussed.

9 May 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
UIUgaitz Iruretagoyena
Ugaitz Iruretagoyena
AGAsier Garcia-Bediaga
Asier Garcia-Bediaga
LMLuis Mir
Luis Mir
HCHaritza Camblong
Haritza Camblong
IVIrma Villar
Irma Villar
Multiphase Dynamic Inductive Power Transfer (D-IPT) systems are capable of achieving uniform power transmission with low control complexity and high efficiency. To achieve acceptable power capabilities, D-IPT systems have to work in resonance configurations. In contrast to transformers, and due to the low coupling coefficient, the compensation is carried out separately in the primary and secondary sides. Consequently, an effect known as bifurcation or pole-splitting is created. This causes extra losses in the semiconductors because Zero Voltage Switching (ZVS) is lost. The main objective of this article is to derive the bifurcation limits for a three-phase D-IPT system. First, the meander coil configuration is introduced. Because this is a system with multiple variables, five assumptions are made to achieve close form equations. Therefore, the 36 inductance system is converted into an ideal three inductance problem. With these assumptions, the equations of the coupling, power and inductance ratio limits are obtained. Afterwards, the repercussion of these assumptions is analyzed using illustrations that depict the input impedance angle for various non-ideal conditions. Finally, a 9kW prototype is used to validate the calculations, analyzing two different operating points: incomplete ZVS and complete ZVS.

3 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
JRJacek Rabkowski
Jacek Rabkowski
MZMariusz Zdanowski
Mariusz Zdanowski
RKRafał Kopacz
Rafał Kopacz
FHFernando Gonzalez Hernando
Fernando Gonzalez Hernando
IVIrma Villar
Irma Villar
ULUxue Larrañaga
Uxue Larrañaga
This article presents a novel method for the dynamic measurement of Coss-VDS characteristic of SiC MOSFET power modules based on the process of charging the output capacitance of the transistors. This technique has been used to determine the Coss-VDS characteristics of medium voltage SiC MOSFET modules, which allows for the extraction of the capacitive current while switching off the transistor. Based on this measurement method, the influence of the turn-off gate voltage V GS-OFF on the Coss-VDS characteristics has been studied, exhibiting an impact on the output capacitance at low drain-source voltages. However, it is shown that the effect of V GS-OFF on the capacitive current and power loss is limited in this area. Finally, the channel current and the capacitive current distribution within the drain current were determined based on the determined Coss-VDS in the experimental test at various switched currents and switching speeds. According to the capacitive charge calculations for several cases, the method’s accuracy is high enough to perform switching power loss estimations for medium voltage power modules to be employed in the design of state-of-the-art power converters. Furthermore, the method is very simple, based on basic capacitance equations, and the required experimental setup is very similar to one used in double-pulse tests.

14 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
AHAlejandro Fernandez Hernandez
Alejandro Fernandez Hernandez
FHFernando Gonzalez Hernando
Fernando Gonzalez Hernando
AGAsier Garcia-Bediaga
Asier Garcia-Bediaga
IVIrma Villar
Irma Villar
GAGonzalo Abad
Gonzalo Abad
In the literature, different DC/DC power electronic converters (PECs) have been found to interconnect high-voltage DC and low-voltage DC grids in the electric power distribution networks of aircraft. In this scenario, the dual-active-bridge (DAB) converter has been shown to be one of the most promising topologies. The main disadvantages of this PEC are the large output capacitance required to satisfy more electric aircraft (MEA) requirements and the high conduction losses produced in low-voltage power devices of (LV). Therefore, this paper proposes analytical models to determine the voltage ripple and root-mean-square (RMS) current in DC bus capacitors of DABs considering different modulation strategies. Moreover, an analysis of the design space in an MEA case study is performed to evaluate the influence of the design variables in power losses of power devices and peak-to-peak voltage ripple in DC bus capacitors. These models are useful for the design stage of this PEC, as well as to enable multi-objective optimization procedures by reducing the computational cost of these methodologies. Furthermore, the exploration of the switching frequency and limit of the modulation angle aid in reducing the resulting volume of the low-voltage DC capacitor.

21 June 2024 in International Journal of Applied Electromagnetics and Mechanics
Verified
Journal Article
Closed access
PDF file
AMAmaiur Mendi-Altube
Amaiur Mendi-Altube
IVIrma Villar
Irma Villar
CCClaudio Carretero
Claudio Carretero
JAJesus Acero
Jesus Acero
This paper describes the procedure of electromagnetic and thermal modeling of an induction hardening load of 42CrMo4 steel. In addition to the temperature and field level dependent physical properties of the material, the magnetic behavior of the load is captured by means of some kind of non-linear impedance boundary condition which simplifies the computational cost of the simulation. The numerical results show the critical behavior around Curie temperature. Finally, a comparison between several simulation results and experimental measurements are provided to assess the usefulness of the proposed electro-thermal simulation.

9 October 2022
Verified
Conference Paper
Closed access
FHFernando Gonzalez Hernando
Fernando Gonzalez Hernando
AJAnder Jauregi
Ander Jauregi
IVIrma Villar
Irma Villar
ARAlejandro Rujas
Alejandro Rujas
LMLuis Mir
Luis Mir
This paper presents a 50 kW bidirectional wireless power transfer system designed to transfer power through a 250 mm airgap to charge a 400 V electric vehicle energy storage system. The charger is based on a series-series compensated inductive power transfer system supplied from the grid, and SiC power semiconductors are employed to deal with the high power transfer and high switching frequency. A control schema is presented to control the power transfer to the energy storage system with both constant-current and constant-voltage modes from the infrastructure side with minimum information from the vehicle side. Experimental tests have been performed to validate the desired target efficiency along the whole power battery voltage range. Furthermore, magnetic field measurements are incorporated to comply with the ICNIRP guidelines.