Renata Longo

Renata Longo

Auto-generated profile, based on publicly available information

Renata Longo

Department of Physics, University of Trieste, Via A. Valerio 2, 34127 Trieste, Italy

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2011 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
RCR C Chen
R C Chen
LRLuigi Rigon
Luigi Rigon
RLR Longo
R Longo
X-ray propagation-based phase-contrast imaging is an attractive phase-sensitive imaging technique that has found applications in many research fields. Here, we report the investigations of a method which can quantitatively reconstruct in 3D the refractive index decrement of a quasi-homogeneous object using single-distance phase-contrast tomography data. The method extends the Born-type approximation phase-retrieval algorithm, which is based on the phase-attenuation duality (ε = δ/β, with constant ε) and suitable for homogeneous objects, to tomography and we study its application to quasi-homogeneous objects. The noise performance and the phase-attenuation duality influences of the method are also investigated. In simulation, the method allows us to quantitatively reconstruct the 3D refractive index decrement for quasi-homogeneous and weakly absorbing samples and it performs well in the practical noise situation. Furthermore, it shows a substantial contrast increase and successfully distinguishes different materials in a quasi-homogeneous and weakly absorbing sample from experimental data, even with inappropriate ε value.

14 July 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SVStevan Vrbaški
Stevan Vrbaški
LPLucia Mariel Arana Peña
Lucia Mariel Arana Peña
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
ATAngelo Taibi
Angelo Taibi
RLRenata Longo
Renata Longo
Objective. Differentiation of breast tissues is challenging in X-ray imaging because tissues might share similar or even the same linear attenuation coefficients μ . Spectral computed tomography (CT) allows for more quantitative characterization in terms of tissue density ( ρ ) and effective atomic number ( Z eff ) by exploiting the energy dependence of μ . The objective of this study was to examine the potential of ρ / Z eff decomposition in spectral breast CT so as to explore the benefits of tissue characterization and improve the diagnostic accuracy of this emerging 3D imaging technique. Approach. In this work, 5 mastectomy samples and a phantom with inserts mimicking breast soft tissues were evaluated in a retrospective study. The samples were imaged at three monochromatic energy levels in the range of 24–38 keV at 5 mGy per scan using a propagation-based phase-contrast setup at SYRMEP beamline at the Italian national synchrotron Elettra. Main results. A custom-made algorithm incorporating CT reconstructions of an arbitrary number of spectral energy channels was developed to extract the density and effective atomic number of adipose, fibro-glandular, pure glandular, tumor, and skin from regions selected by a radiologist. Significance. Preliminary results suggest that, via spectral CT, it is possible to enhance tissue differentiation. It was found that adipose, fibro-glandular and tumorous tissues have average effective atomic numbers (5.94 ± 0.09, 7.03 ± 0.012, and 7.40 ± 0.10) and densities (0.90 ± 0.02, 0.96 ± 0.02, and 1.07 ± 0.03 g cm −3 ) and can be better distinguished if both quantitative values are observed together.

1 December 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
VTVittorio Di Trapani
Vittorio Di Trapani
ABAlberto Bravin
Alberto Bravin
Francesco BrunFrancesco Brun
Francesco Brun
DDD. Dreossi
D. Dreossi
RLR. Longo
R. Longo
PDP. Delogu
P. Delogu

28 October 2002 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SFS Fabbri
S Fabbri
ATAngelo Taibi
Angelo Taibi
RLR Longo
R Longo
MMM Marziani
M Marziani
AOAlessandro Olivo
Alessandro Olivo
MGM Gambaccini
M Gambaccini
Dual-energy radiography is an effective technique that allows removal of contrast between pairs of materials in order to display details of interest on a uniform background. In mammographic images the detection of small nodules is often impeded by obscuring background 'clutter' resulting from the contrast between normal tissues (glandular and adipose) in their neighbourhood. We consider whether it could be possible to apply dual-energy radiography to the breast, which is hypothetically principally composed of three tissues, glandular, adipose and cancerous, in order to remove the contrast due to the distribution of normal tissues and, as a consequence, to enhance the intrinsic contrast of the pathology. The purpose of this work is to test the limitations of dual-energy radiography on a three-component phantom under optimum conditions of the source and detector. We use a synchrotron monochromatic beam, produced at the ELETTRA synchrotron facility (Trieste, Italy), and an imaging plate detector, in order to acquire two images at low and high energies of a phantom composed of polyethylene, plexiglas and water. For evaluation of the potential of this procedure we studied the signal-to-noise ratio (SNR) of polyethylene and water on a set of images obtained by applying the dual-energy procedure. We found that the SNR of polyethylene and water is around the detectability threshold (according to Rose's criteria) at the contrast cancellation angles. Finally we evaluated the air entrance dose required for this double exposure, resulting in 0.81 mGy for the low-energy image and 0.01 mGy for the high-energy image. To obtain the same image quality for a standard breast of 5.5 cm, mean glandular doses of 3.50 mGy and 0.03 mGy at 17 keV and at 34 keV, respectively, are required.

6 November 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SSShobhit Sharma
Shobhit Sharma
SVStevan Vrbaški
Stevan Vrbaški
MBMridul Bhattarai
Mridul Bhattarai
EAEhsan Abadi
Ehsan Abadi
RLRenata Longo
Renata Longo
ESEhsan Samei
Ehsan Samei
Objective. This study describes the development, validation, and integration of a detector response model that accounts for the combined effects of x-ray crosstalk, charge sharing, and pulse pileup in photon-counting detectors. Approach. The x-ray photon transport was simulated using Geant4, followed by analytical charge sharing simulation in MATLAB. The analytical simulation models charge clouds with Gaussian-distributed charge densities, which are projected on a 3×3 pixel neighborhood of interaction location to compute detected counts. For pulse pileup, a prior analytical method for redistribution of energy-binned counts was implemented for delta pulses. The x-ray photon transport and charge sharing components were validated using experimental data acquired on the CdTe-based Pixirad-1/Pixie-III detector using monoenergetic beams at 26, 33, 37, and 50 keV. The pulse pileup implementation was verified with a comparable Monte Carlo simulation. The model output without pulse pileup was used to generate spatio-energetic response matrices for efficient simulation of scanner-specific photon-counting CT (PCCT) images with DukeSim, with pulse pileup modeled as a post-processing step on simulated projections. For analysis, images for the Gammex multi-energy phantom and the XCAT chest phantom were simulated at 120 kV, both with and without pulse pileup for a range of doses (27–1344 mAs). The XCAT images were evaluated qualitatively at 120 mAs, while images for the Gammex phantom were evaluated quantitatively for all doses using measurements of attenuation coefficients and Calcium concentrations. Main results. Reasonable agreement was observed between simulated and experimental spectra with Mean Absolute Percentage Error Values (MAPE) between 10 % and 31 % across all incident energies and detector modes. The increased pulse pileup from increased dose affected attenuation coefficients and calcium concentrations, with an effect on calcium quantification as high as MAPE of 28%. Significance. The presented approach demonstrates the viability of the model for enabling VITs to assess and optimize the clinical performance of PCCT.

1 September 2003 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABAnna Bergamaschi
Anna Bergamaschi
MPM. Prest
M. Prest
EVE. Vallazza
E. Vallazza
FAF. Arfelli
F. Arfelli
DDD. Dreossi
D. Dreossi
ECE. Castelli
E. Castelli