13 September 2024 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
JBJakub Baran
Jakub Baran
SBSteven Bass
Steven Bass
JCJarosław Choiński
Jarosław Choiński
NCNeha Chug
Neha Chug
Ewa Łucja StępieńEwa Łucja Stępień
Ewa Łucja Stępień
Positronium is abundantly produced within the molecular voids of a patient’s body during positron emission tomography (PET). Its properties dynamically respond to the submolecular architecture of the tissue and the partial pressure of oxygen. Current PET systems record only two annihilation photons and cannot provide information about the positronium lifetime. This study presents the in vivo images of positronium lifetime in a human, for a patient with a glioblastoma brain tumor, by using the dedicated Jagiellonian PET system enabling simultaneous detection of annihilation photons and prompt gamma emitted by a radionuclide. The prompt gamma provides information on the time of positronium formation. The photons from positronium annihilation are used to reconstruct the place and time of its decay. In the presented case study, the determined positron and positronium lifetimes in glioblastoma cells are shorter than those in salivary glands and those in healthy brain tissues, indicating that positronium imaging could be used to diagnose disease in vivo.

2 May 2025 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
DKDeepak Kumar
Deepak Kumar
SSSushil Sharma
Sushil Sharma
EBErmias Yitayew Beyene
Ermias Yitayew Beyene
NCNeha Chug
Neha Chug
KEKavya Valsan Eliyan
Kavya Valsan Eliyan
In state-of-the-art positron emission tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and parapositronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening avenues for exploring polarization correlations in PET as a diagnostic indicator.

2 January 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
PMPawel Moskal
Pawel Moskal
ECEryk Czerwiński
Eryk Czerwiński
JRJuhi Raj
Juhi Raj
SBSteven D. Bass
Steven D. Bass
EBErmias Y. Beyene
Ermias Y. Beyene
WWWojciech Wiślicki
Wojciech Wiślicki
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of 10−4 signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

31 December 2023 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Closed access
MDManish Das
Manish Das
WMWiktor Mryka
Wiktor Mryka
EBErmias Y. Beyene
Ermias Y. Beyene
SPSzymon Parzych
Szymon Parzych
SSSushil Sharma
Sushil Sharma
PMPawel Moskal
Pawel Moskal
The positronium imaging technique represents a potential enhancement of the PET imaging method. Its core principle involves employing a β+ radiation source that emits additional gamma (γ) quanta referred to as prompt gamma. Our aim is to evaluate the capability to differentiate between annihilation and prompt gamma emissions, a vital aspect of positronium imaging. For this purpose, the selected isotopes should enable high efficiency and purity in detecting both prompt gamma and annihilation gamma. The assessment of the efficiency in identifying prompt and annihilation photons for various isotopes, which are potentially superior candidates for β+ + γ emitters, is conducted through toy Monte-Carlo simulation utilizing the cross-section formula for photon-electron scattering. In this article, we have performed calculations for efficiency and purity values across different isotopes under ideal conditions and examined how these values evolve as we incorporate the fractional energy resolution into the analysis. Ultimately, the primary goal is to determine the energy threshold that optimizes both efficiency and purity, striking a balance between accurately identifying and recording events of interest while minimizing contamination from undesired events.

31 December 2023 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Closed access
EBErmias Yitayew Beyene
Ermias Yitayew Beyene
MDManish Das
Manish Das
MDMartyna Durak-Kozica
Martyna Durak-Kozica
GKGRZEGORZ Korcyl
GRZEGORZ Korcyl
WMWiktor Mryka
Wiktor Mryka
PMPawel Moskal
Pawel Moskal
The modular J-PET scanner, comprising 24 compact and versatile modules, each consisting of 13 plastic strips with four SiPM detectors at the ends, represents a powerful tool for clinical applications in nuclear medical imaging. This study presents preliminary results from the exploration of simultaneous dual-isotope imaging using the modular J-PET system. Our approach involved two isotopes: 68Ge, characterized by a ringlike shape, and 22Na, exhibiting a point-like shape. The imaging was based on double-coincidence and triple-coincidence events. In the double coincidence case, both isotopes contributed comparably, whereas in the triple coincidence case 22Na dominated due to the prompt gamma being emitted with 100% of positron emissions, unlike 68Ga, where the prompt gamma was emitted in only 1.3% of cases after positron emission. In this work we present direct 2γ images determined for two-signal events and images for three-signal events, with two signals from annihilation photons and one from a prompt gamma. These results showcase the preliminary findings from simultaneous dual-isotope imaging of 68Ga and 22Na isotopes using the modular J-PET scanner, which will be presented and discussed.

23 December 2024 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Closed access
MDManish Das
Manish Das
RBReimund Bayerlein
Reimund Bayerlein
SSSushil Sharma
Sushil Sharma
SPSzymon Parzych
Szymon Parzych
SNSzymon Niedźwiecki
Szymon Niedźwiecki
PMPawel Moskal
Pawel Moskal
Objective: Positron emission tomography (PET) is a widely used medical imaging technique that allows for non-invasive imaging of metabolic processes. However, traditional PET scanners rely on costly inorganic scintillators that limit their accessibility, especially in light of emerging long axial field-of-view devices. The modular J-PET scanner, an innovative alternative, uses 50-cm-long plastic scintillator strips, offering a cost-effective and modular solution. In this study we develop and assess the PET data correction techniques required for quantitative image reconstruction. Methods: We present methods for attenuation correction, random coincidence correction using the delayed time window (DTW) technique and scatter correction based on Monte Carlo simulations. Phantom studies using the NEMA IQ phantom were performed to qualitatively evaluate these corrections. Results: The results demonstrate that our implemented corrections for attenuation and random and scattered coincidences successfully improve the uniformity of tracer distribution in homogenous volumes and significantly reduce undesired activity in cold regions. Despite limitations in sensitivity and axial resolution, the applied correction techniques effectively enhance image quality, providing promising results for future applications. Conclusions: These findings highlight the potential of the modular J-PET system to offer affordable PET imaging and to pave the way for a total-body PET scanner based on plastic scintillators. Future work will focus on quantitative validation and the implementation of these corrections for human subject imaging.