An usual material, EN-GJL-250 cast iron, used for automotive braking systems, was covered with a ceramic material (105NS-1 aluminium oxide) using an industrial deposition system (Sulzer Metco). The main reason was to improve the corrosion and wear (friction) resistance properties of the cast-iron. Samples were prepared by mechanical grinding and sandblasting before the deposition. We applied two and four passes (around 12–15 µm by layer) each at 90° obtaining ceramic coatings of 30 respectively 60 µm. The surface of the samples (with ceramic coatings) was investigated using scanning electron microscopy (SEM), dispersive energy spectroscopy (EDS) and X-ray diffraction (XRD). Scratch and micro-hardness tests were performed using CETR-UMT-2 micro-tribometer equipment. The better corrosion resistance of the base material was obtained by applying the ceramic coating. The results present a better corrosion resistance and a higher coefficient of friction of the coated samples.
The high yttria content of a stabilized zirconia (YSZ) (38 wt% Y2O3) coating was deposited by atmospheric plasma spraying (APS) from Metco 207 powders on an Inconel 718 (Ni-based superalloy) substrate. As a metal coating connection, a layer of cermet powder (Ni-20% Al—410NS) was used before the ceramic layer deposition. The electro-chemical corrosion resistance of these materials was tested using Inconel cylinders with a diameter of 10 mm and a thickness of 1 mm, with and without the ceramic layer. Linear and cyclic measurements were obtained in H2SO4 electrolyte media at pH = 2. Electro-impedance spectroscopy (EIS) experiments were performed on the sample covered with the ceramic layer to evaluate the interface behavior. Scanning electron microscopy (SEM), along with equipment to determine chemical composition, and an energy dispersive spectrometry (EDS) detector were used to characterize the material surface before and after corrosion tests. It was observed that the corrosion resistance of Inconel was influenced by the bonding layer and the ceramic coating.
A new functional Fe-30Mn-5Si-xCu (x = 1.5 and 2 wt%) biomaterial was obtained from the levitation induction melting process and evaluated as a biodegradable material. The degradation characteristics were assessed in vitro using immersion tests in simulated body fluid (SBF) at 37 ± 1 °C, evaluating mass loss, pH variation that occurred in the solution, open circuit potential (OCP), linear and cyclic potentiometry (LP and CP), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and nano-FTIR. To obtain plates as samples, the cast materials were thermo-mechanically processed by hot rolling. Dynamic mechanical analysis (DMA) was employed to evaluate the thermal properties of the smart material. Atomic force microscopy (AFM) was used to show the nanometric and microstructural changes during the hot rolling process and DMA solicitations. The type of corrosion identified was generalized corrosion, and over the first 3–5 days, an increase in mass was observed, caused by the compounds formed at the metal–solution interface. The formed compounds were identified mainly as oxides that passed into the immersion liquid. The degradation rate (DR) was obtained as a function of mass loss, sample surface area and immersion duration. The dynamic mechanical behavior and dimensions of the sample were evaluated after 14 days of immersion. The nanocompounds found on the surface after atmospheric corrosion and immersion in SBF were investigated with the Neaspec system using the nano-FTIR technique.
5 July 2021 in Archives of Metallurgy and Materials
A new non-sparking metallic material, Cu-Ti, with applications in potentially explosive environments is proposed as an alternative to CuBe, to reduce the processing and toxic effects of Be. Using high-purity Cu and Ti materials, a Cu (~3–4 wt%) Ti alloy with good chemical and structural homogeneity was fabricated in an induction furnace under an Ar atmosphere. The hot-rolled material was tested in an explosive gas mixture (10% H2 or 6.5% CH4) under extremely severe wear tests for 15,000 cycles, and no hot sparks were produced to ignite the medium. The material was investigated as hot-rolled plates (600 s at 950 °C and 10% reduction). The microstructures and surface of the wear test samples were investigated by light optical microscopy (LOM) and scanning electron microscopy (SEM). The chemical compositions were determined by energy dispersive spectrometry (EDS). The corrosion behavior was studied using electrochemical techniques: open-circuit, linear, and cyclic potentiometry in saline electrolyte solutions. The mechanical properties, such as microhardness and friction coefficient, were determined using UMT equipment. The results showed that the alloy is suitable for applications requiring non-ignition properties, with good hot rolling deformability and chemical composition homogeneity. Regarding the corrosion analysis and mechanical properties of the experimental CuTi alloy, minor differences were observed between the cast- and hot-rolled material.
The paper analyzes the occurrence of evenly spaced cracks on the surface of lamellar specimens of Fe-28Mn-6Si-5Cr (mass %) shape-memory alloy (SMA), during cold rolling. The specimens were hot rolled and normalized and developed cold rolling cracks with an approximate spacing of about 1.3 mm and a depth that increased with the thickness-reduction degree. At normalized specimens, X-ray diffraction patterns revealed the presence of multiple crystallographic variants of brittle α′ body-bcc martensite, which could be the cause of cold-rolling cracking. Both normalized and cold-rolled specimens were analyzed using scanning electron microscopy SEM. SEM micrographs revealed the presence of several crystallographic variants of α′-body-centered cubic (bcc) and ε hexagonal close-packed (hcp) martensite plates within a γ-face-centered cubic (fcc) austenite matrix in a normalized state. High-resolution SEM, recorded after 25% thickness reduction by cold-rolling, emphasized the ductile character of the cracks by means of an array of multiple dimples. After additional 33% cold-rolling thickness reduction, the surface of crack walls became acicular, thus revealing the fragile character of failure. It has been argued that the specimens cracked in the neutral point but preserved their integrity owing to the ductile character of γ-fcc austenite matrix.