Patrik Klučiar

Mr. Patrik Klučiar

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2025 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
MKMichal Krbaťa
Michal Krbaťa
MKMarcel Kohutiar
Marcel Kohutiar
JEJana Escherová
Jana Escherová
PKPatrik Klučiar
Patrik Klučiar
ZSZbyněk Studený
Zbyněk Studený
ĽTĽudmila Timárová
Ľudmila Timárová
The aim of this work is to perform a detailed dilatometric analysis of the decomposition of austenite during the cooling process using experimentally derived continuous cooling transformation (CCT) diagrams for two specific tool steels, X153CrMoV12 Bohdan Bolzano, Bratislava, Slovakia and 100MnCrW4. The dilatometric curves were compared with metallographic evaluations using scanning electron microscopy (SEM). In addition, hardness measurements were performed to obtain additional information about the mechanical properties of the materials. All experimental work was performed using a DIL 805A. The accuracy of the resulting CCT diagrams was verified by comparing them with those calculated with the JMatPro software v12.4. The cooling rates ranged from 20 °C/s to 0.01 °C/s, depending on the specific type of steel tested. The novelty of this research is the combination of experimental and simulation methods to analyze the influence of alloying elements on the kinetics of phase transformations in tool steels. It was found that one of the most significant factors affecting the CCT diagrams is the weight percentage of alloying elements in the steels. These results clearly show that increasing the weight percentage of the content of alloying elements has a significant impact on the accuracy of the simulation results derived from the JMatPro software.

25 March 2026 in Metals
Verified
Journal Article
Open access
PDF file
JEJana Escherová
Jana Escherová
MKMichal Krbaťa
Michal Krbaťa
DKDaniel Krizan
Daniel Krizan
MKMarcel Kohutiar
Marcel Kohutiar
Bohdan TrembachBohdan Trembach
Bohdan Trembach
CCChristian Commenda
Christian Commenda
This study evaluates the tribological properties of lean medium manganese advanced high-strength steel (AHSS) subjected to five different heat treatment processes. The tests were conducted under dry reciprocating conditions using the ball-on-flat method, with a G40 steel ball, a 10 N load, and 1000 cycles at room temperature. Friction behavior, wear resistance, nanoindentation hardness, surface roughness, and microstructural changes were examined. The results showed that heat treatment significantly influenced the microstructure and hardness of the samples. The Mn-Q sample, with fresh martensite, achieved the highest hardness (483 HV5), while the Mn-Q&P 500 °C sample had the lowest (336 HV5), with a 30% reduction due to tempering. The Mn-HR 500 °C sample showed the highest surface roughness (Sa = 1.876 μm) due to microstructural heterogeneity. Despite similar coefficients of friction across all samples (0.55–0.57), the Mn-Q&P 500 °C sample exhibited the best wear resistance, 18% higher than the Mn-HR 500 °C variant. Wear mechanisms were identified as a combination of abrasion and oxidation, where the latter slightly reduced the coefficient of friction (COF) but increased surface degradation. These findings highlight the potential of lean medium Mn AHSS for tribological applications, offering a favorable balance of wear resistance and frictional stability.

6 December 2025 in Ceramics International
Verified
Journal Article
Closed access
KKKamil Kleszcz
Kamil Kleszcz
WSWitold Szymanski
Witold Szymanski
ŁKŁukasz Kaczmarek
Łukasz Kaczmarek
DKDaniel Kottfer
Daniel Kottfer
PKPatrik Klučiar
Patrik Klučiar
Karol KyziolKarol Kyziol
Karol Kyziol

13 October 2025 in Materials
Verified
Journal Article
Open access
PDF file
DKDaniel Kottfer
Daniel Kottfer
Karol KyziolKarol Kyziol
Karol Kyziol
MKMaria Kanuchova
Maria Kanuchova
MKMarta Kianicová
Marta Kianicová
MŽMichal Žitňan
Michal Žitňan
PKPatrik Klučiar
Patrik Klučiar
This study examines the impact of varying pulse conditions on the properties of titanium diboride (TiB2) coatings deposited by high-power impulse magnetron sputtering (HiPIMS). The coatings were prepared on steel substrates using an industrial-scale system. During the experiments, the HiPIMS frequency and pulse width were systematically varied to examine their influence on the coating’s microstructural, mechanical, and tribological properties. The obtained results show a correlation between process parameters and coating performance. A maximum hardness of 39.7 GPa and a coefficient of friction (CoF) as low as 0.68 were achieved. The best combination of mechanical properties was observed for coatings prepared in a frequency range of 600–1000 Hz and with a pulse width of 50 µs. Notably, the optimal tribological properties and surface roughness were obtained at 800 Hz and a 50 µs pulse width. This work demonstrates that fine-tuning HiPIMS pulse conditions is crucial for achieving high-quality TiB2 coatings with enhanced functional performance.

Verified
Journal Article
Open access
PDF file
JEJana Escherová
Jana Escherová
MKMichal Krbaťa
Michal Krbaťa
DKDaniel Krizan
Daniel Krizan
PKPatrik Klučiar
Patrik Klučiar
MKMarcel Kohutiar
Marcel Kohutiar
MKMariana Kuffová
Mariana Kuffová
This study evaluates the effect of different precipitation-hardening regimes on the microstructure, hardness, and tribological behaviour of W720 maraging steel. Experimental specimens were aged at temperatures ranging from 460 to 490 °C for 3–16 h following solution annealing. Tribological tests were performed using the Ball-on-Flat method under dry sliding conditions against a G40 steel ball. The worn surfaces were analysed using LSCM, SEM, and EDS. Aging increased the hardness from 323 HV1 to 580–606 HV1 and reduced the coefficient of friction from approximately 0.75 to 0.63–0.71. The lowest nominal specimen wear volume was measured for the as-received, solution-annealed W720 condition (0.011 mm3), followed by HT490_6 (0.012 mm3); these values were compared descriptively without inferential statistical testing. However, the reference specimen produced a narrow, locally deepest wear track and caused the highest wear of the counter-body. The highest wear volume of the specimen was recorded for HT480_3 (0.027 mm3), while HT460_8x2 combined the highest hardness and the lowest coefficient of friction with a high wear volume. The dominant wear mechanism was a combination of abrasive grooving, adhesive damage, and tribo-oxidation. The results demonstrated that the tribological resistance of W720 is not governed by hardness alone, but rather by the interplay between microstructure, wear-track geometry, wear-product morphology, and the distribution of wear between the specimen and the counter-body.