Emiliano Schena

Dr. Emiliano Schena

Laboratory of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, 00128 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea NicolòAndrea Nicolò
Andrea Nicolò
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Emiliano SchenaEmiliano Schena
Emiliano Schena
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
Respiratory rate is a fundamental vital sign that is sensitive to different pathological conditions (e.g., adverse cardiac events, pneumonia, and clinical deterioration) and stressors, including emotional stress, cognitive load, heat, cold, physical effort, and exercise-induced fatigue. The sensitivity of respiratory rate to these conditions is superior compared to that of most of the other vital signs, and the abundance of suitable technological solutions measuring respiratory rate has important implications for healthcare, occupational settings, and sport. However, respiratory rate is still too often not routinely monitored in these fields of use. This review presents a multidisciplinary approach to respiratory monitoring, with the aim to improve the development and efficacy of respiratory monitoring services. We have identified thirteen monitoring goals where the use of the respiratory rate is invaluable, and for each of them we have described suitable sensors and techniques to monitor respiratory rate in specific measurement scenarios. We have also provided a physiological rationale corroborating the importance of respiratory rate monitoring and an original multidisciplinary framework for the development of respiratory monitoring services. This review is expected to advance the field of respiratory monitoring and favor synergies between different disciplines to accomplish this goal.

21 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Andrea NicolòAndrea Nicolò
Andrea Nicolò
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
SSSergio Silvestri
Sergio Silvestri
Emiliano SchenaEmiliano Schena
Emiliano Schena
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject’s body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.

24 August 2020 in IEEE Access
Verified
Journal Article
Open access
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Catia LeitaoCatia Leitao
Catia Leitao
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
MSMarzhan Sypabekova
Marzhan Sypabekova
Emiliano SchenaEmiliano Schena
Emiliano Schena
In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of nextgeneration medical devices and healthcare system.

31 August 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
ACArianna Carnevale
Arianna Carnevale
IPIlaria Piergentili
Ilaria Piergentili
ABAlessandra Berton
Alessandra Berton
VCVincenzo Candela
Vincenzo Candela
Vincenzo DenaroVincenzo Denaro
Vincenzo Denaro
Background: Rotator cuff retear (RCR) is one of the main postoperative drawbacks. RCR can be considered a multifactorial issue, which causes are related either to biological than biomechanical factors. The aim of this study was to define the incidence of RCR after surgical treatment at different time points and to identify the main factors influencing the postoperative rotator cuff (RC) healing.Methods: A systematic review and meta-analysis were performed following the PRISMA guidelines. A comprehensive search of the literature was carried out in July 2020, using PubMed and Cochrane Library databases. Only level 1 and 2 clinical evidence studies were included. Studies were included if patients with preoperative repairable full-thickness RC tears were treated surgically, and if studies reported postoperative RCR confirmed by imaging diagnostic. The association between timing of retear and follow-up time points were investigated using an inverse-variance method of pooling data. A subgroup meta-analysis was performed using the DerSimonian and Laird method for the estimation of the between-study variance, i.e., τ2. The association between retear rate after surgery and patients’ age, preoperative tear size, fatty infiltration, postoperative rehabilitation protocol, surgical techniques, and RC repairs was determined by expressing the effect measure in terms of odds ratio (OR) with 95% confidence interval (CI). The Mantel-Haenszel method with 95% CIs was used.Results: Thirty-one articles were included in this study. The percentage of RCR after surgery was 15% at 3 months follow-up, 21% at 3–6 months follow-up, 16% at 6–12 months follow-up, 21% at 12–24 months follow-up, 16% at follow-up longer than 24 months. The main factors influencing RC healing are both patient-related (i.e., age, larger tear size, fatty infiltration) and not patient-related (i.e., postoperative rehabilitation protocol, surgical techniques, and procedures).Conclusions: Postoperative RC healing is influenced by patient-related and non-patient-related factors. Further high-level clinical studies are needed to provide highly relevant clinical results.

22 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Emiliano SchenaEmiliano Schena
Emiliano Schena
Daniele TosiDaniele Tosi
Daniele Tosi
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Elfed LewisElfed Lewis
Elfed Lewis
Taesung KimTaesung Kim
Taesung Kim
During recent decades, minimally invasive thermal treatments (i.e., Radiofrequency ablation, Laser ablation, Microwave ablation, High Intensity Focused Ultrasound ablation, and Cryo-ablation) have gained widespread recognition in the field of tumor removal. These techniques induce a localized temperature increase or decrease to remove the tumor while the surrounding healthy tissue remains intact. An accurate measurement of tissue temperature may be particularly beneficial to improve treatment outcomes, because it can be used as a clear end-point to achieve complete tumor ablation and minimize recurrence. Among the several thermometric techniques used in this field, fiber optic sensors (FOSs) have several attractive features: high flexibility and small size of both sensor and cabling, allowing insertion of FOSs within deep-seated tissue; metrological characteristics, such as accuracy (better than 1 °C), sensitivity (e.g., 10 pm·°C−1 for Fiber Bragg Gratings), and frequency response (hundreds of kHz), are adequate for this application; immunity to electromagnetic interference allows the use of FOSs during Magnetic Resonance- or Computed Tomography-guided thermal procedures. In this review the current status of the most used FOSs for temperature monitoring during thermal procedure (e.g., fiber Bragg Grating sensors; fluoroptic sensors) is presented, with emphasis placed on their working principles and metrological characteristics. The essential physics of the common ablation techniques are included to explain the advantages of using FOSs during these procedures.

18 October 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
Domenico FormicaDomenico Formica
Domenico Formica
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
GPGiovanni Di Pino
Giovanni Di Pino
Emiliano SchenaEmiliano Schena
Emiliano Schena
During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine.